2007
DOI: 10.1016/j.jchromb.2007.09.008
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous quantification of GMP, AMP, cyclic GMP and cyclic AMP by liquid chromatography coupled to tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
23
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 30 publications
(25 citation statements)
references
References 32 publications
2
23
0
Order By: Relevance
“…As cGMP is a very polar molecule, retention on reversed phase columns is difficult and requires a nearly 100% aqueous mobile phase [12], ion pairing [10] or reversed phase columns with hydrophilic endcapping [13]. On the other hand, porous graphitic carbon columns provide good retention behavior with polar compounds such as cGMP.…”
Section: Chromatography and Mass Spectrometrymentioning
confidence: 99%
See 1 more Smart Citation
“…As cGMP is a very polar molecule, retention on reversed phase columns is difficult and requires a nearly 100% aqueous mobile phase [12], ion pairing [10] or reversed phase columns with hydrophilic endcapping [13]. On the other hand, porous graphitic carbon columns provide good retention behavior with polar compounds such as cGMP.…”
Section: Chromatography and Mass Spectrometrymentioning
confidence: 99%
“…Two of the published methods [10,11] do not focus solely on cGMP, but profile many different phosphorylated nucleotides simultaneously and need therefore time-consuming chromatographic procedures. Another method based on LC-MS/MS [12] is restricted to enzyme solutions and uses no I.S. Recently, a method quantifying cGMP from human plasma utilizing an isotope labeled analogue of cGMP as I.S.…”
Section: Introductionmentioning
confidence: 99%
“…However an other assay using positive ESI mode for the quantification of AMP, GMP, cAMP and cyclic GMP (cGMP) in human platelet Table 3 Performance and validation parameters for the quantification of endogenous nucleotides and nucleotide analogs using UV detection mode. extracts have shown a better sensitivity than the negative ion mode [65].…”
Section: Detection Modementioning
confidence: 99%
“…The sample obtained after a protein precipitation step could be directly injected into an analytical device [42,47,57,65]. However, in some cases, the sample underwent concentration by evaporation [46,49,60] or a freeze-drying [4,56].…”
Section: Analysis Of Endogenous Nucleotidesmentioning
confidence: 99%
See 1 more Smart Citation