2014
DOI: 10.1556/achrom.26.2014.4.12
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous quantification of salvianolic acid B and tanshinone IIA of salvia tropolone tablets by UPLC-MRM-MS/MS for pharmacokinetic studies

et al.

Abstract: Summary.A rapid and sensitive ultraperformance liquid chromatography-multiple reaction monitoring-multi-stage/mass spectrometry (UPLC-MRM-MS/MS) method has been developed for simultaneous quantification of salvianolic acid B and tanshinone IIA of salvia tropolone tablets in dog plasma. This was achieved by performing quantification using the MRM acquisition with two channels of MRM-MS/MS and MS full scan for more accuracy qualitative results, and the fragmentation transitions of m/z 295→249, 191 for tanshinone… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 29 publications
0
1
0
Order By: Relevance
“…Similar to the detection of many drug molecules at nanogram level, it is difficult to quantitatively detect LSB in plasma by HPLC coupled with a UV–Visible detector due to its low bioavailability and high binding affinity to plasma proteins [ 20 ]. In a previous study, LSB of 300–90,000 pg/mL in dog plasma was effectively detected via removing the plasma interference by using LC/MS spectrometry in MRM mode [ 26 ]. In this study, LSB at nanogram level in rat plasma was successfully monitored via avoiding plasma interference through the selection of parent and corresponding product ions of LSB (m/z 717 → 519, 321) under the same technical approach.…”
Section: Discussionmentioning
confidence: 99%
“…Similar to the detection of many drug molecules at nanogram level, it is difficult to quantitatively detect LSB in plasma by HPLC coupled with a UV–Visible detector due to its low bioavailability and high binding affinity to plasma proteins [ 20 ]. In a previous study, LSB of 300–90,000 pg/mL in dog plasma was effectively detected via removing the plasma interference by using LC/MS spectrometry in MRM mode [ 26 ]. In this study, LSB at nanogram level in rat plasma was successfully monitored via avoiding plasma interference through the selection of parent and corresponding product ions of LSB (m/z 717 → 519, 321) under the same technical approach.…”
Section: Discussionmentioning
confidence: 99%