2002
DOI: 10.1016/s0301-2115(02)00061-1
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous use of intrapartum fetal pulse oximetry and amnioinfusion in meconium stained amniotic fluid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
4
0
2

Year Published

2003
2003
2008
2008

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 15 publications
0
4
0
2
Order By: Relevance
“…Oxymétrie. L'oxymétrie peut être utilisée en cas de liquide méconial [77,104,[123][124][125][126]. Ses performances ne sont pas altérées par la présence d'un liquide amniotique méconial contrairement à celles du pH au scalp [104] (NP3).…”
Section: Moyen De Surveillanceunclassified
See 1 more Smart Citation
“…Oxymétrie. L'oxymétrie peut être utilisée en cas de liquide méconial [77,104,[123][124][125][126]. Ses performances ne sont pas altérées par la présence d'un liquide amniotique méconial contrairement à celles du pH au scalp [104] (NP3).…”
Section: Moyen De Surveillanceunclassified
“…Une équipe a comparé, en cas de liquide méconial, l'efficacité de l'association de l'oxymétrie de pouls à l'amnio-infusion (débutée si la saturation était inférieure à 30 % pendant 10 minutes) à la surveillance par enregistrement du RCF continu [124]. Le taux de césariennes pour suspicion d'hypoxie foetale était inférieur dans le groupe oxymétrie et amnio-infusion sans modification du taux global de césariennes.…”
Section: Moyen De Surveillanceunclassified
“…CTG is a widely employed indirect way of detecting fetal hypoxia based on the response of the fetal nervous system. It may detect the fetus at risk of compromise 5 . However, low specifity in spite of its high sensitivity, variable and inconsistent interpretation even by experts in this field, and being an indirect way of fetal assessment reduce its clinical efficacy.…”
Section: Introductionmentioning
confidence: 99%
“…It may detect the fetus at risk of compromise. 5 However, low specifity in spite of its high sensitivity, variable and inconsistent interpretation even by experts in this field, and being an indirect way of fetal assessment reduce its clinical efficacy. High rates of false positive findings of CTG have unfortunately led to increased rates of cesarean deliveries due to nonreassuring FHR patterns which are not always accurate indicators of fetal hypoxia.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation