2017
DOI: 10.1002/mop.30479
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneously two‐parameter measurement using tilted fiber grating and long period fiber grating

Abstract: We proposed and demonstrated a complex sensor, which combined a tilted fiber Bragg grating and a long period fiber grating. We used this sensor to measure the surrounding refractive index and temperature of an unknown liquid. The measured range of the temperature and environmental refractive index were 30–70°CC and 1.33–1.4, respectively. The measured results have linearly trend with high sensitivity. © 2017 Wiley Periodicals, Inc. Microwave Opt Technol Lett 59:1122–1125, 2017

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
2
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 11 publications
0
2
0
Order By: Relevance
“…By utilizing different grating sensitivities at different positions, multiparameter sensing can be achieved. Compared to traditional measurement systems that combine different gratings [88][89][90], the sensor-based RFGA reduces complexity and cost and improves mechanical strength. The strong random scattering characteristic of RFGA is also able to solve the problem of traditional FBG being limited by broadband light source, which causes difficulty to achieve high-resolution monitoring.…”
Section: Random Weak Grating Array As a Sensitive Elementmentioning
confidence: 99%
“…By utilizing different grating sensitivities at different positions, multiparameter sensing can be achieved. Compared to traditional measurement systems that combine different gratings [88][89][90], the sensor-based RFGA reduces complexity and cost and improves mechanical strength. The strong random scattering characteristic of RFGA is also able to solve the problem of traditional FBG being limited by broadband light source, which causes difficulty to achieve high-resolution monitoring.…”
Section: Random Weak Grating Array As a Sensitive Elementmentioning
confidence: 99%
“…The dual wavelength matrix method uses two FBGs with different temperatures or strain sensitivities. Both FBGs simultaneously sense the external temperature and strain, such as FBG and tilted fiber Bragg grating (TFBG) [19], FBG and long-period fiber grating (LPFG) [20], TFBG, and LPFG [21]. However, the length of the TFBG and LPFG is generally in the centimeter range, making it difficult to achieve a high-density array.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, the RI measurement without considering the thermal effect may cause the analyte to be misjudged. In 2017, we proposed a complex sensor combined with an FBG and LFPG for RI and temperature detection [18].…”
Section: Introductionmentioning
confidence: 99%