2014
DOI: 10.1021/cg401380a
|View full text |Cite
|
Sign up to set email alerts
|

Single Crystal to Single Crystal Polymerization of a Self-Assembled Diacetylene Macrocycle Affords Columnar Polydiacetylenes

Abstract: This manuscript describes a single-crystal-tosingle-crystal polymerization of the dihydrate of diacetylene 1 (1•2H 2 O) to give an unusual polydiacetylene (PDA) structure that consists of aligned nanotubes, with each covalently bonded nanotube having two parallel PDA chains that run parallel down opposite sides of a channel defined by the macrocycle. Each PDA nanotube is connected with four other columns via amide hydrogen bonds with an N-(H)•••O distance of 2.888(4) Å. Such well-ordered polymers should displa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
35
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 54 publications
(40 citation statements)
references
References 95 publications
(132 reference statements)
5
35
0
Order By: Relevance
“…The diyne systems are parallel as requested; nevertheless, the angle of the reactive carbons and mostly their distance separations are not favorable, being distorted and much too long, respectively (Figure 4). Topochemical polymerization of diacetylene is also prevented because there is no long range parallel stacking of diynes [58][59][60][61][62][63][64][65][66][67]. …”
Section: Crystallographic Studiesmentioning
confidence: 99%
“…The diyne systems are parallel as requested; nevertheless, the angle of the reactive carbons and mostly their distance separations are not favorable, being distorted and much too long, respectively (Figure 4). Topochemical polymerization of diacetylene is also prevented because there is no long range parallel stacking of diynes [58][59][60][61][62][63][64][65][66][67]. …”
Section: Crystallographic Studiesmentioning
confidence: 99%
“…Stabilities of the polymers were verified by thermogravimetric analysis (TGA) . For this purpose, polymer of 2 was subjected to TGA under inert argon atmosphere between 27 and 500 °C, at a heating rate of 10 °C min −1 .…”
Section: Resultsmentioning
confidence: 99%
“…Hollow tubular nanostructures offer a variety of applications in chemistry, biochemistry and materials science as specific molecular reaction vessels [41], screening activities of membrane channels and the nanoscale fluidic transport systems [42]. However, highly stable and programmable organic nanotubes (ONT) are very rare [43,44].…”
Section: Peptoid-based Crystalline Nanotubementioning
confidence: 99%