2021
DOI: 10.1016/j.aca.2021.338797
|View full text |Cite
|
Sign up to set email alerts
|

Single-event tandem ICP-mass spectrometry for the quantification of chemotherapeutic drug-derived Pt and endogenous elements in individual human cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(14 citation statements)
references
References 52 publications
0
14
0
Order By: Relevance
“…73 Furthermore, ICP-QMS/QMS has been covered by principle studies and reviews on the ICP-MS reaction/collision cell technology, 72,74,75 gas chromatography (GC-) ICP-MS, 76 and high performance liquid chromatography (HPLC-) ICP-MS for quantitative profiling analysis of metalloids in biological samples, 77 respectively. ion-gas molecule reaction, 73 isotope, 3,4,22-24,26-28,43-47,62-66,68, single particle, 5,6,15,31,40,[54][55][56][57] and chemical speciation, 7,8,[10][11][12]16,76,77 respectively.…”
Section: References Investigatedmentioning
confidence: 99%
See 3 more Smart Citations
“…73 Furthermore, ICP-QMS/QMS has been covered by principle studies and reviews on the ICP-MS reaction/collision cell technology, 72,74,75 gas chromatography (GC-) ICP-MS, 76 and high performance liquid chromatography (HPLC-) ICP-MS for quantitative profiling analysis of metalloids in biological samples, 77 respectively. ion-gas molecule reaction, 73 isotope, 3,4,22-24,26-28,43-47,62-66,68, single particle, 5,6,15,31,40,[54][55][56][57] and chemical speciation, 7,8,[10][11][12]16,76,77 respectively.…”
Section: References Investigatedmentioning
confidence: 99%
“…Due to spectral interferences, the determination of lower concentrations (ng/mL order or lower) of P, S, Si, Cl, Br, and I is often challenging for traditional ICP-MS. Measurement by ICP-QMS/QMS at massshift mode using O2 as the cell gas permitted a better performance for analysis of these element and has been reported for P, 15,19,34,41,45,[49][50][51][52] S, 15,19,34,40,41,45,[44][45][46][47][48][49][50][51][52] Si, 19,34,45,50,52 Cl, 34,45,52 Br, 34,41 and I, 34,41 respectively.…”
Section: Reaction Gases Used In the Measurement By Icp-qms/qmsmentioning
confidence: 99%
See 2 more Smart Citations
“…Single-cell analysis based on inductively coupled plasma–mass spectrometry (ICP-MS) allows investigating heterogeneous cell populations with regard to cell numbers, cell types, and functionality. 1 , 2 Over the last decade, elemental single-cell analysis of cells in suspension 3 9 has evolved to the established strategy of mass cytometry, successfully applied in clinical routines. More recently, the potential of imaging strategies by laser ablation (LA)-ICPMS was recognized and has triggered a wave of exciting studies.…”
Section: Introductionmentioning