2013 IEEE International Conference of IEEE Region 10 (TENCON 2013) 2013
DOI: 10.1109/tencon.2013.6718460
|View full text |Cite
|
Sign up to set email alerts
|

Single-phase-to-ground fault detection in wind farm collector line using transient phase current criterion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 1 publication
0
4
0
Order By: Relevance
“…Finally, the maximum and minimum values of each element in D are eliminated, and the CCD feature of line j is computed using (12).…”
Section: Cross-correlation Distance Featurementioning
confidence: 99%
See 1 more Smart Citation
“…Finally, the maximum and minimum values of each element in D are eliminated, and the CCD feature of line j is computed using (12).…”
Section: Cross-correlation Distance Featurementioning
confidence: 99%
“…It can be further categorized into steady‐state and transient methods. Common steady‐state methods encompass the zero‐sequence active power direction method [11], group comparison method [12], and the harmonic component method [13] etc. Meanwhile, common transient methods include the transient direction method [14] and the transient energy method [15] etc.…”
Section: Introductionmentioning
confidence: 99%
“…It is worth mentioning that all kinds of faults have a direct effect on the power system generation, hence the smart grid has been proposed to give a good solution for the system under faults, in addition, the system has a good dynamic response under the dynamic change of the system wither was a fault or load change. A lot of electrical systems have been studied based on different faults [10], [11], [12], [13], [14]. In [10] effective algorithms have been presented to locate the fault for the two-parallel transmission line.…”
Section: Introductionmentioning
confidence: 99%
“…In [10] effective algorithms have been presented to locate the fault for the two-parallel transmission line. In [11] the behavior of the system voltage and load currents have been studied based on different faults with linear and non-linear loads, in [12] a novel method of the single-phase-to-ground fault has been presented. In [13] double line to the ground has been applied, in addition, Fault resistance values are determined, In [14] the tripping of the line without fault has been discussed and this tripping is more dangerous than a three-phase permanent ground fault, the criterion used in this previous study showed that the inertia time constants, transfer impedance angle and initial relative phase angle between two machines are the important items to determine any machines most effected by fault.…”
Section: Introductionmentioning
confidence: 99%