2009
DOI: 10.1038/nphys1250
|View full text |Cite
|
Sign up to set email alerts
|

Single-shot carrier–envelope phase measurement of few-cycle laser pulses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
252
0
3

Year Published

2012
2012
2019
2019

Publication Types

Select...
5
5

Relationship

1
9

Authors

Journals

citations
Cited by 267 publications
(255 citation statements)
references
References 37 publications
0
252
0
3
Order By: Relevance
“…The electric field of the laser pulse can be approximated as E(t) = E 0 cos 2 (t/τ) cos(ωt + φ), where E 0 is the field amplitude, ω is the carrier frequency, τ is the pulse duration, and φ is the CEP. Combining a reaction microscope (REMI) 20 with a newly developed phase-tagging technique 21 , we obtained the CEP of the laser pulse for each and every ionization event 22 recorded with the REMI. The laser was focussed to a maximum instantaneous intensity of I 0 = cε 0 E 0 2 = (3.0 ± 0.6)×10 14 W cm − 2 into a cold supersonic gas jet of neutral argon atoms located in the centre of the REMI.…”
Section: Resultsmentioning
confidence: 99%
“…The electric field of the laser pulse can be approximated as E(t) = E 0 cos 2 (t/τ) cos(ωt + φ), where E 0 is the field amplitude, ω is the carrier frequency, τ is the pulse duration, and φ is the CEP. Combining a reaction microscope (REMI) 20 with a newly developed phase-tagging technique 21 , we obtained the CEP of the laser pulse for each and every ionization event 22 recorded with the REMI. The laser was focussed to a maximum instantaneous intensity of I 0 = cε 0 E 0 2 = (3.0 ± 0.6)×10 14 W cm − 2 into a cold supersonic gas jet of neutral argon atoms located in the centre of the REMI.…”
Section: Resultsmentioning
confidence: 99%
“…The laser intensity was kept stable on the level of 10%. The CEP of each laser pulse was recorded by sending a fraction of the laser beam (20 mJ) into a single-shot stereographic above-threshold ionization (Stereo-ATI) phase meter 32 . A detailed description of the CEP measurement and CEP tagging techniques can be found in ref.…”
Section: Methodsmentioning
confidence: 99%
“…Typically in such methods, CEP values are estimated by measuring the CEP dependence of highly nonlinear signal and comparing the results with numerical simulations. For example, plasmonic sensors 40,41 , stereo-ATI (above-threshold-ionisation) [42][43][44][45] , velocity map imaging [46][47][48][49] and high harmonic generation 50,51 have been used for such purposes. With the help of a polarization gating technique, the CEP of multi-cycle pulses can be obtained 52 .…”
Section: Discussionmentioning
confidence: 99%