2021
DOI: 10.1117/1.oe.60.12.124110
|View full text |Cite
|
Sign up to set email alerts
|

Single-shot high speed aerial chromatic confocal metrology sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…In combination with the 4f-system to filter non-focused wavelength components and this spectral analysis unit, a full field areal chromatic confocal measurement is performed. This procedure is the key method for obtaining the height information encoded into the spectral domain without decoding the spectral information into a spatial dimension 22 , 23 …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In combination with the 4f-system to filter non-focused wavelength components and this spectral analysis unit, a full field areal chromatic confocal measurement is performed. This procedure is the key method for obtaining the height information encoded into the spectral domain without decoding the spectral information into a spatial dimension 22 , 23 …”
Section: Methodsmentioning
confidence: 99%
“…This procedure is the key method for obtaining the height information encoded into the spectral domain without decoding the spectral information into a spatial dimension. 22,23 To obtain an encoding of the axial depth information into the wavelength domain, a hyperchromatic objective is employed. Figure 2 show the design [Fig.…”
Section: Methodsmentioning
confidence: 99%
“…The spectral's first momentum obtained is close to the maximum of the spectral distribution and therefore uniquely correlates with the surface height to be measured. [10][11] [12] 3. METHODS…”
Section: Principlesmentioning
confidence: 99%
“…The existing prototype allows for the determination of the approximate width of the Gaussian function at a defined object height of 20 nm under these conditions. [12] A simulation was conducted to analyse how the spectrum of the light source affects the measurement system. To simplify the system, the following assumptions were made.…”
Section: Spectral Optimization Of the Light Sourcementioning
confidence: 99%
“…Building upon this concept, Korbinian Prause et al designed a spectral confocal measurement sensor comprising four primary components: illumination, hyperchromatic objectives, a pinhole multiplexer unit, and an optical spectral analysis unit. Utilizing a two-dimensional grid pattern of polarization points encoding surface height into frequency or wavelength domain of light, the system achieved high-speed, high-resolution primary surface measurements without mechanical depth scanning 4 . Dawoon et al proposed a frequency-scanning source-based chromatic aberration confocal microscope system employing a wavelength-scanning laser as the light source.…”
Section: Introductionmentioning