Cleo: 2014 2014
DOI: 10.1364/cleo_si.2014.sf1e.2
|View full text |Cite
|
Sign up to set email alerts
|

Single-shot Measurement of the Complete Temporal Intensity and Phase of Supercontinuum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
10
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 3 publications
0
10
0
Order By: Relevance
“…The comparison between techniques introduced in this paper and already-existing single shot phase and amplitude measurement devices (e.g. time stretch [12,44], XFROG [2,8], SEA-SPIDER [23,24], SEA-TADPOLE [4] or STARFISH [5]) represents a complex question that is out of the scope of the present paper and that deserves further analysis.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The comparison between techniques introduced in this paper and already-existing single shot phase and amplitude measurement devices (e.g. time stretch [12,44], XFROG [2,8], SEA-SPIDER [23,24], SEA-TADPOLE [4] or STARFISH [5]) represents a complex question that is out of the scope of the present paper and that deserves further analysis.…”
Section: Discussionmentioning
confidence: 99%
“…This kind of detection is needed for the characterization of various fundamental phenomena such as e.g. supercontinuum [7,8], optical rogue waves (RWs) [9][10][11], or soliton dynamics in mode-locked lasers [12,13]. The task remains a particulary challenging open problem when femtosecond resolution and long time windows are simultaneously required.…”
mentioning
confidence: 99%
“…However, real-time techniques allowing the full-field characterization of an MI field are still required. In this context, we note that the recently-reported single-shot measurement of the complete temporal intensity and phase of a supercontinuum using an adapted frequency-resolved optical gating technique may represent a very significant step forward 32 .…”
Section: Discussionmentioning
confidence: 99%
“…For stochastic radiation that exhibits dynamic behaviour, all differences between pulses resulting from noise will be cancelled out in measurements averaged over many of them. Single-shot techniques 25 and direct real-time intensity measurements are required to reveal the internal stochastic structure of individual pulses.…”
mentioning
confidence: 99%