2015
DOI: 10.1039/c4an01648c
|View full text |Cite
|
Sign up to set email alerts
|

Single step derivatization with CF3 enone of thiophene at ambient temperature to determine propellant grade hydrazines: a study by GC and GC-MS

Abstract: A simple, highly selective and rapid gas chromatography method (packed column with flame ionization detection) has been developed to determine hydrazine and monomethylhydrazine individually and for selective determination of hydrazine in the UH 25 mixture in organic medium. This method is based on the derivatization of hydrazine (at ambient temperature) with 1,1,1-trifluoro-4-(3-thienyl) (CF3 enone) in the absence of catalyst/buffer which leads to the formation of corresponding pyrazolidine/pyrazoline/pyrazole… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 38 publications
0
4
0
Order By: Relevance
“…This D value is relatively high as compared to some other electrodes, 21,22,33 and almost the same as that reported at a ZnO/ CNTs/HPDB modied carbon paste electrode, which suggests a faster hydrazine diffusion at this Ni 3 modied electrode. The catalytic rate constant (k cat , M À1 s À1 ) for the electrochemical reaction between hydrazine and the redox sites of Ni 3 molecules can also be evaluated by chronoamperometry through eqn (10) as follows: 17,21…”
Section: Electrochemical Behavior Of Hydrazine At Ni 3 /Au Electrodesmentioning
confidence: 99%
See 2 more Smart Citations
“…This D value is relatively high as compared to some other electrodes, 21,22,33 and almost the same as that reported at a ZnO/ CNTs/HPDB modied carbon paste electrode, which suggests a faster hydrazine diffusion at this Ni 3 modied electrode. The catalytic rate constant (k cat , M À1 s À1 ) for the electrochemical reaction between hydrazine and the redox sites of Ni 3 molecules can also be evaluated by chronoamperometry through eqn (10) as follows: 17,21…”
Section: Electrochemical Behavior Of Hydrazine At Ni 3 /Au Electrodesmentioning
confidence: 99%
“…1,2 However, hydrazine is highly toxic for human health, causes liver, kidneys, and central nervous system damages. 5,6 Various methods, such as spectrophotometric determination, 4, 6-9 electrochemiluminescence, 5 gas chromatography (GC) or GC tandem mass spectrometry (GC-MS), 10 and high performance liquid chromatography (HPLC) or LC-MS methods, 11,12 have been established for the detection of hydrazine. 5,6 Various methods, such as spectrophotometric determination, 4, 6-9 electrochemiluminescence, 5 gas chromatography (GC) or GC tandem mass spectrometry (GC-MS), 10 and high performance liquid chromatography (HPLC) or LC-MS methods, 11,12 have been established for the detection of hydrazine.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Various methods for detecting hydrazine hydrate have already been established, such as spectrophotometry, electrochemiluminescence, GC-MS, and high-performance liquid chromatography (HPLC) [5][6][7][8][9], which display excellent repeatability and sensitivity. However, they may be inconvenient due to the high-cost and time-consuming running.…”
Section: Introductionmentioning
confidence: 99%