2020
DOI: 10.1029/2019pa003844
|View full text |Cite
|
Sign up to set email alerts
|

Single Tests of Thermocline Dwelling Foraminifera Globorotalia inflata as Recorder of Upper Water Column Structure off Mauritania (NW Africa): Methodology and Paleoceanographic Use

Abstract: Thermocline‐dwelling foraminifera calcify over a depth range of several hundred meters; analysis of individual shells therefore allows insight to the hydrography of the upper water column. We analyzed δ18O, δ13C, and Mg/Ca of individual tests of the planktonic foraminifera Globorotalia inflata from a sediment core (GeoB7926‐2) obtained from 20°N in the eastern tropical Atlantic. To facilitate sample throughput, tests were cleaned before Mg/Ca analysis using a pipette robot. The eight samples came from five tim… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 110 publications
(157 reference statements)
0
1
0
Order By: Relevance
“…Analyses of Mn/Ca and Fe/Ca were used as indicators of Fe-Mn crusts/coatings, while Nd/Ca analyses (Table 1) were used to estimate approximate Nd concentrations of particular samples to determine the dominant Nd carrier phases in the analyzed samples (e.g., Kuhnert & Mulitza, 2011;Skinner et al, 2019;Yu et al, 2005). We set critical thresholds of <0.2 mmol/mol for Al/Ca and <1.6 mmol/mol for Sr/Ca (e.g., Barker et al, 2003;Johnstone et al, 2020), (Ayache et al, 2021;Bialik et al, 2019;Colin et al, 2021;Dubois-Dauphin et al, 2017;Duhamel et al, 2020;Freydier et al, 2001;Garcia-Solsona & Jeandel, 2020;Jiménez-Espejo et al, 2015;Osborne et al, 2010;Tachikawa et al, 2004;Wu et al, 2019) whereas the thresholds of <1,500 μmol/mol for Fe/Ca, <150 μmol/mol for Mn/Ca, and <40 μmol/mol for Ba/Ca were selected arbitrarily based on our experience, mainly because there is no general agreement regarding the current application. The elemental analyses were performed using the Element 2™ sector field HR-ICP-MS (Thermo Scientific™) housed at the Institute of Geology of the Czech Academy of Sciences (IG CAS) following the methods outlined in detail in Marchitto (2006).…”
Section: Foraminiferal Samples and Elemental Ratios Analysesmentioning
confidence: 99%
“…Analyses of Mn/Ca and Fe/Ca were used as indicators of Fe-Mn crusts/coatings, while Nd/Ca analyses (Table 1) were used to estimate approximate Nd concentrations of particular samples to determine the dominant Nd carrier phases in the analyzed samples (e.g., Kuhnert & Mulitza, 2011;Skinner et al, 2019;Yu et al, 2005). We set critical thresholds of <0.2 mmol/mol for Al/Ca and <1.6 mmol/mol for Sr/Ca (e.g., Barker et al, 2003;Johnstone et al, 2020), (Ayache et al, 2021;Bialik et al, 2019;Colin et al, 2021;Dubois-Dauphin et al, 2017;Duhamel et al, 2020;Freydier et al, 2001;Garcia-Solsona & Jeandel, 2020;Jiménez-Espejo et al, 2015;Osborne et al, 2010;Tachikawa et al, 2004;Wu et al, 2019) whereas the thresholds of <1,500 μmol/mol for Fe/Ca, <150 μmol/mol for Mn/Ca, and <40 μmol/mol for Ba/Ca were selected arbitrarily based on our experience, mainly because there is no general agreement regarding the current application. The elemental analyses were performed using the Element 2™ sector field HR-ICP-MS (Thermo Scientific™) housed at the Institute of Geology of the Czech Academy of Sciences (IG CAS) following the methods outlined in detail in Marchitto (2006).…”
Section: Foraminiferal Samples and Elemental Ratios Analysesmentioning
confidence: 99%