2022
DOI: 10.1016/j.aeaoa.2022.100182
|View full text |Cite
|
Sign up to set email alerts
|

Size distribution and concentration of indoor culturable bacterial and fungal bioaerosols

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
9
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 33 publications
1
9
0
1
Order By: Relevance
“…Moreover, to evaluate the impact of microbes' sizes for breathing areas, a TCR TECORA Pollution Check IMP-6 Bio (6 stages aerodynamic particle sizing) was used in a 100 m 2 test room at 28. www.nature.com/scientificreports/ from 1.1 to 0.65 μm. Stages reflects the location of depositing of inhalable bacteria in the human lungs, where 1-2 altogether represents bacteria of the upper airway and 3-6 the respirable microbial particles 40,41 . Collection was performed in the so-called human breathing zone, considered at 1.5 m above the floor and 1.0 m from the walls.…”
Section: Indoor Air Spread Microbial Counting In Colony Forming Units...mentioning
confidence: 99%
“…Moreover, to evaluate the impact of microbes' sizes for breathing areas, a TCR TECORA Pollution Check IMP-6 Bio (6 stages aerodynamic particle sizing) was used in a 100 m 2 test room at 28. www.nature.com/scientificreports/ from 1.1 to 0.65 μm. Stages reflects the location of depositing of inhalable bacteria in the human lungs, where 1-2 altogether represents bacteria of the upper airway and 3-6 the respirable microbial particles 40,41 . Collection was performed in the so-called human breathing zone, considered at 1.5 m above the floor and 1.0 m from the walls.…”
Section: Indoor Air Spread Microbial Counting In Colony Forming Units...mentioning
confidence: 99%
“…Air quality in the indoor environment can be influenced by biotic agents such as microorganisms, spores, mites, and pollen. With these particle types general termed bioaerosols (Jeong et al, 2022). These…”
Section: Abstract Aspergillus • Books Collection • Cascade Impactors ...mentioning
confidence: 99%
“…1). The impactor was operated at the height of 1.5 m so that particulates would be captured at the respirable level (Grzyb et al, 2022;Jeong et al, 2022), at a flow rate of 28.3 l/min verified by a rotameter attached to the device.…”
Section: Samplingmentioning
confidence: 99%
“…These results are in agreement with previous studies. The authors determined with 6-stage Andersen impactor that average value for fungal aerosol diameters were between 2.1 µm and 4.7 µm [5] or between 1.1 µm and 3.3 µm [25]. The cut-off diameter of bacterial aerosols were less than 2.1 µm [25].…”
Section: Measurements Of Microbial Concentrationmentioning
confidence: 99%