2008
DOI: 10.1007/s00134-008-1180-y
|View full text |Cite
|
Sign up to set email alerts
|

Sleep monitoring in the intensive care unit: comparison of nurse assessment, actigraphy and polysomnography

Abstract: Actigraphy and behavioural assessment by the bedside nurse are inaccurate and unreliable methods to monitor sleep in critically ill patients.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
167
0
4

Year Published

2011
2011
2018
2018

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 140 publications
(177 citation statements)
references
References 35 publications
6
167
0
4
Order By: Relevance
“…12 Wrist actigraphy is a potentially cheap and non-labor-intensive mode for monitoring sleep wake and agitation, 31 though it has not yet been fully validated in ICU. 32,33 Additionally, there may have been a recruitment and selection bias that limits the generalizability of the results to the ICU population as a whole. Only subjects discharged on Monday to Friday mornings from 08:00 to 12:00 were invited to participate, and the sample of 100 patients was mainly a convenience sample.…”
Section: Discussionmentioning
confidence: 99%
“…12 Wrist actigraphy is a potentially cheap and non-labor-intensive mode for monitoring sleep wake and agitation, 31 though it has not yet been fully validated in ICU. 32,33 Additionally, there may have been a recruitment and selection bias that limits the generalizability of the results to the ICU population as a whole. Only subjects discharged on Monday to Friday mornings from 08:00 to 12:00 were invited to participate, and the sample of 100 patients was mainly a convenience sample.…”
Section: Discussionmentioning
confidence: 99%
“…While studies have assessed the accuracy of actigraphy in ICU patients, as well as in controlled sleep conditions, no known study of the accuracy of actigraphy in general medicine patients has been conducted. 35,36 Another study limitation was the rate of Actiwatch removal or failure (24%); the most common reason was removal of the Actiwatch for a procedure, such as MRI, as clinical activities took precedence over our research. It is possible that the patients who consented to the sleep study differ from those that did not consent, raising the concern for selection bias.…”
Section: Discussionmentioning
confidence: 99%
“…Although previous research involving the ICU patient population is limited and frequently involved small numbers, this technology may have a useful application in specific clinical situations and may not be suitabe for all ICU patients as indicated by Beecroft et al [63]. In their study involving mechnically ventilated patients (n=12) the accuracy of actigraphy compared with PSG was reported to be less than 65%.…”
Section: Behavioural Assessment Of Sleep Disturbancementioning
confidence: 99%