2005 European Conference on Power Electronics and Applications 2005
DOI: 10.1109/epe.2005.219738
|View full text |Cite
|
Sign up to set email alerts
|

Sliding mode control of DVR with minimized energy injection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…2) Case 2 When the voltage of the DVR V DVR2 is injected with a phase angle γ and magnitude to guarantee the load voltage V L2 at the desired magnitude with a phase angle shift δ, the resulting load current I L2 will have a corresponding phase angle shift δ as illustrated in Fig. 1 [11] - [19]. The angle between I L2 and V L2 remains unchanged when the load is not changed.…”
Section: A Types Of Dvr Injectionmentioning
confidence: 99%
See 2 more Smart Citations
“…2) Case 2 When the voltage of the DVR V DVR2 is injected with a phase angle γ and magnitude to guarantee the load voltage V L2 at the desired magnitude with a phase angle shift δ, the resulting load current I L2 will have a corresponding phase angle shift δ as illustrated in Fig. 1 [11] - [19]. The angle between I L2 and V L2 remains unchanged when the load is not changed.…”
Section: A Types Of Dvr Injectionmentioning
confidence: 99%
“…The dynamic voltage restorer (DVR) is a commonly used device to deal with voltage-related power quality problems [5] - [19]. DVRs are connected near the load side through long and often unreliable feeders.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A comparison between feedback, feed-forward, and composite controllers is provided in Table 9 [138]. The calculated DVR voltage or load voltage in the feedback controller is affected by a voltage controller, like Proportional-Resonant (PR) [139], H infinity ( ) [140,141], Repetitive [67,142,143], Predictive [7,144,145], combined Feed-Forward and State Feedback [146], State Variable [147], Feedback Linearization [148], Sliding Mode (SMC) [149][150][151][152], and Metaheuristic Algorithms like Fuzzy Logic (FLC) [95,153,154], Hybrid Genetic Algorithm (GA) and FLC (GA FCL) [155], Cuckoo Search (CS) [156], Chaotic Accelerated PSO (CAPSO) [157], Artificial Neural Network (ANN) [46,158,159], to name just a few. There are also other reference generation methods like Symmetric Component Estimation [133,134], Instantaneous Power Theory (PQR) [135,136], and Phasor Parameter Estimation [137].…”
Section: Reference Generation and Modulation Stagesmentioning
confidence: 99%
“…Load voltage THD was calculated for each voltage sag condition during DVR operation. In Piatek et al, SMC‐based DVR is simulated through MATLAB Simulink, and the performance is also analyzed. It provides satisfactory and fast response compared with conventional method.…”
Section: Introductionmentioning
confidence: 99%