2016 Online International Conference on Green Engineering and Technologies (IC-GET) 2016
DOI: 10.1109/get.2016.7916614
|View full text |Cite
|
Sign up to set email alerts
|

Smart grid and power quality (PQ) issues

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…T. S. Saggu, et al [18], the author just dealt with solving the harmonics using the UPQC system and did not give a detailed design or study in this regard. In review papers [6], [17], [20] The author has only reviewed some PQ problems.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…T. S. Saggu, et al [18], the author just dealt with solving the harmonics using the UPQC system and did not give a detailed design or study in this regard. In review papers [6], [17], [20] The author has only reviewed some PQ problems.…”
Section: Discussionmentioning
confidence: 99%
“…With the rapid spread of non-linear loads, they have become the primary reason for harmonic distortion in-branch currents, which, in due course, leads to harmonic voltage distortion at distribution system nodes/buses. Voltage sag, a severe PQ degradation, is an immediate or drastic drop in the root-mean-square (RMS) voltage value spanning from 0.1 to 0.9 per-unit and sustains within this abnormal drop from 0.5 cycles to a couple of seconds [6]. Voltage sags that last less than a 0.5 cycle duration are considered transients.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The impacts of power quality problems are voltage surges/spikes, voltage dips, under voltage, high-voltage spikes, frequency variation, power sag, electrical line noise, brownouts, blackouts, very short interruptions, long interruptions, voltage swell and harmonic distortion. (Jolhe et al , 2016; Wang et al , 2017). As per Indian Electrical Electronics Manufacturer Association (IEEMA) article (IEEMA, 2012 Article Electromagnetic Compatibility Power Electronics n.d.), Sag is the serious and major problem among all other power quality issues as shown in Figure 1.…”
Section: Introductionmentioning
confidence: 99%
“…Obviously, it is deteriorated from the voltage/current power quality (PQ) imperfections, which includes voltage and/or current harmonic distortions, reactive power mitigation, power factor improvement, voltage-sag, voltage swell, un-balancing loading. These PQ issues in multi-feeder distribution systems are not a new things but the awareness of these PQ issues has been increased at current situation by end-user consumers [2].…”
Section: Introductionmentioning
confidence: 99%