2019
DOI: 10.1016/j.ymssp.2018.10.024
|View full text |Cite
|
Sign up to set email alerts
|

Smart panel with sweeping and switching piezoelectric patch vibration absorbers: Experimental results

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(8 citation statements)
references
References 55 publications
0
8
0
Order By: Relevance
“…In a recent study, the first six flexural modes of a thin rectangular panel were controlled with five piezoelectric actuators (which were connected to either switching or sweeping time-varying RLC-shunts) [398]. Typically, the shunted piezoelectric actuators are tuned to reduce the vibrations of the plates at specific resonance frequencies, but in their study the R and L values are either commuted between specific values, or varied in a given range, to either switch over to given resonance, or sweep over a range frequency range, to provide broadband control.…”
Section: The Foundational Studiesmentioning
confidence: 99%
“…In a recent study, the first six flexural modes of a thin rectangular panel were controlled with five piezoelectric actuators (which were connected to either switching or sweeping time-varying RLC-shunts) [398]. Typically, the shunted piezoelectric actuators are tuned to reduce the vibrations of the plates at specific resonance frequencies, but in their study the R and L values are either commuted between specific values, or varied in a given range, to either switch over to given resonance, or sweep over a range frequency range, to provide broadband control.…”
Section: The Foundational Studiesmentioning
confidence: 99%
“…From this result they developed an adaptive shunt using a controller based on the extremum seeking algorithm capable of adjusting online the resistance and inductance emulated by an synthetic impedance to maximize the time-averaged electric power dissipated by the PVA [14]. In addition to adaptive shunts, which are usually based on active circuits, switching shunts based on semi-active circuits such as state switching and synchronized switch damping have also been explored in the literature to improve the PVA robustness [15][16][17][18]. The major drawbacks of switching shunts are the high order frequency signals required to control the switching circuits and the acoustic disturbances during operation [1].…”
Section: Introductionmentioning
confidence: 99%
“…Matten et al (2014), Nečásek et al (2016, 2017), and Silva (2018) investigated various electronic architectures to implement a DVA, and discussed how to set up its analog and digital parts. Dal Bo et al (2019) configured a digital unit to realize vibration absorbers with swept and switched characteristics. Recently, this concept was applied to metamaterials by Sugino et al (2018, 2020) and Yi et al (2020), and to nonlinear shunt damping (Raze et al, 2020).…”
Section: Introductionmentioning
confidence: 99%