2018
DOI: 10.1109/tpel.2017.2661965
|View full text |Cite
|
Sign up to set email alerts
|

Soft-Switched Modulation Techniques for an Isolated Bidirectional DC–AC

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
13
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 51 publications
(13 citation statements)
references
References 19 publications
0
13
0
Order By: Relevance
“…However, in the output stage switches are voltagecurrent-bidirectional switches which must be commutated such that never short the input port voltage and cut the output port current path. For this purpose, four-step commutation process based on the sign of switches voltage or current is proposed in the literature which is more complicated than that of conventional voltage source converters [16,18,19].…”
Section: Commutation Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…However, in the output stage switches are voltagecurrent-bidirectional switches which must be commutated such that never short the input port voltage and cut the output port current path. For this purpose, four-step commutation process based on the sign of switches voltage or current is proposed in the literature which is more complicated than that of conventional voltage source converters [16,18,19].…”
Section: Commutation Methodsmentioning
confidence: 99%
“…However, the main drawback of the HFAC converters is their large number of active switches. Due to a large number of active switches, commutation and modulation methods of these types of converters are too complex compared with their conventional multi-stage DC/AC converters [15][16][17][18][19][20][21][22][23].…”
Section: Introductionmentioning
confidence: 99%
“…In case of isolated systems, line‐/high‐frequency transformer is used for galvanic isolation and voltage step‐up aspects, 1,2 as isolated systems are rigid, more efficient, and reliable. On the other hand, isolated systems using line‐frequency transformers degrade the overall efficiency 3 …”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, isolated systems using line-frequency transformers degrade the overall efficiency. 3 Alternatively, transformer-less two-stage nonisolated topologies can be employed, where the first stage boosts the input DC voltage using DC-DC converter while the second stage applies DC/AC conversion using VSI. The employed VSI requires an output filter to produce a pure sinusoidal output voltage.…”
mentioning
confidence: 99%
“…These capacitors can be large and expensive [8]. Otherwise, there are different topologies that perform DC-AC conversion in an isolated and bidirectional way without the need for an intermediate stage of conversion [9][10][11][12][13][14][15].…”
Section: Introductionmentioning
confidence: 99%