2014
DOI: 10.1073/pnas.1400015111
|View full text |Cite
|
Sign up to set email alerts
|

Solid MRI contrast agents for long-term, quantitative in vivo oxygen sensing

Abstract: Targeted MRI contrast agents have proven useful in research and clinical studies for highlighting specific metabolites and biomarkers [Davies GL, et al. (2013) Chem Commun (Camb) 49(84):9704-9721] but their applicability in serial imaging is limited owing to a changing concentration postinjection. Solid enclosures have previously been used to keep the local concentration of contrast agent constant, but the need to surgically implant these devices limits their use [Daniel K, et al. (2009) Biosens Bioelectron 2… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
29
0
2

Year Published

2014
2014
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 19 publications
(32 citation statements)
references
References 30 publications
1
29
0
2
Order By: Relevance
“…As a straightforward example, hyperpolarized [1‐ 13 C]‐dehydrascorbate can be reduced to vitamin C, which changes the 13 C chemical shift by 3.8 ppm . The incorporation of O 2 into a siloxane polymeric matrix causes a change in electronic state of the polymer, causing a decrease in T 1 relaxation time constant of the system . As a more complex example, a Eu(III) chelate with an N ‐methylquinolinium ligand or an anthryl ligand can be reduced, which causes a change in the electron density at the coordinating ligand.…”
Section: Examples Of Responsive Mri Contrast Agentsmentioning
confidence: 99%
“…As a straightforward example, hyperpolarized [1‐ 13 C]‐dehydrascorbate can be reduced to vitamin C, which changes the 13 C chemical shift by 3.8 ppm . The incorporation of O 2 into a siloxane polymeric matrix causes a change in electronic state of the polymer, causing a decrease in T 1 relaxation time constant of the system . As a more complex example, a Eu(III) chelate with an N ‐methylquinolinium ligand or an anthryl ligand can be reduced, which causes a change in the electron density at the coordinating ligand.…”
Section: Examples Of Responsive Mri Contrast Agentsmentioning
confidence: 99%
“…The most commonly used siloxane is hexamethyldisiloxane (HMDSO), although similar compounds have also been investigated 106. 107 HMDSO was chosen as an optimal PISTOL contrast agent largely owing to its similarity to the known HFB, which is used in 19 F relaxometry. The molecular symmetry of the siloxane and the lower electronegativity of silicon provide a single NMR signal that is spectrally well separated from those arising from tissue.…”
Section: Resonance Techniquesmentioning
confidence: 99%
“…For example, Liu et al. recently demonstrated that embedded contrast agents chemically directed to target organs can achieve longer retention times for longitudinal tissue oxygenation monitoring 107…”
Section: Resonance Techniquesmentioning
confidence: 99%
See 2 more Smart Citations