2006
DOI: 10.1556/jpc.19.2006.2.8
|View full text |Cite
|
Sign up to set email alerts
|

Solid-phase extraction and TLC quantification of enrofloxacin, oxytetracycline, and trimethoprim in wastewater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 10 publications
0
6
0
Order By: Relevance
“…In this study, amoxicillin was detected in only one sample; this is because that B-lactam drug has chemically unstable rings that readily undergo hydrolysis and may not be detected easily in the finished water [10,26]. Furthermore, many studies documented the prevalence of amoxicillin and ciprofloxacin resistant bacteria in river water, waste water, and drinking water [16,45,46]. Limit of detection either is defined as the characterization of the general chemical ingredients at very low concentration or recognizes only one chemical measurements process [40].…”
Section: Resultsmentioning
confidence: 95%
“…In this study, amoxicillin was detected in only one sample; this is because that B-lactam drug has chemically unstable rings that readily undergo hydrolysis and may not be detected easily in the finished water [10,26]. Furthermore, many studies documented the prevalence of amoxicillin and ciprofloxacin resistant bacteria in river water, waste water, and drinking water [16,45,46]. Limit of detection either is defined as the characterization of the general chemical ingredients at very low concentration or recognizes only one chemical measurements process [40].…”
Section: Resultsmentioning
confidence: 95%
“…Physical and chemical tests were done on Borcˇec water, whose characterisation was presented elsewhere [5].…”
Section: Sample Preparationmentioning
confidence: 99%
“…TMP is of diaminopyrimidine compound class. It is a dihydrofolate reductase inhibitor, commonly prescribed with sulfonamides antimicrobial agents as synergist and mainly used in the prophylaxis and treatment of urinary tract infections [5].…”
Section: Introductionmentioning
confidence: 99%
“…The following new solid phase extraction (SPE) methods were reported in the review period: extraction of veterinary drugs from wastewater using Strata-X cartridges prior to analysis on CN modified silica gel with 0.05 M H 2 C 2 O 4 −MeOH (81:19) mobile phase with videodensitometric quantification ; extraction on C-18 cartridges for quality control of Rhodiola rosea root extracts [silica gel layer, ethyl acetate−MeOH−water (77:13:10) mobile phase, UV slit scanning densitometry] ; extraction of sulfonamides and trimethoprim from water on Waters Oasis copolymer hydrophobic−lipophilic balanced (HLB) cartridges [silica gel layer, chloroform−MeOH (89:11) mobile phase, videodensitometric quantification] ; and extraction of enrofloxacin, oxytetracycline, and trimethoprim from wastewater on polystyrene−divinylbenzene (SDB) Empore disks [HPTLC CNF layer, 0.05 M H 2 C 2 O 4 −MeOH (65:35) mobile phase, videodensitometric UV quantification] .…”
Section: Apparatus and Techniquesmentioning
confidence: 99%