Solid-phase microextraction of phthalate esters from aqueous media by electrochemically deposited carbon nanotube/polypyrrole composite on a stainless steel fiber

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
40
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 136 publications
(42 citation statements)
references
References 47 publications
2
40
0
Order By: Relevance
“…One of the strategies used to enhance thermal stability of PPY was synthesis multiwalled carbon nanotubes-PPY composite. Compared to PPY, multiwalled carbon nanotubes-PPY composite showed higher thermal stability and charge delocalization properties [21,22]. Also, the changing of synthesis medium from aqueous to organic medium led to enhance thermal stability of PPY fibers [23].…”
Section: Introductionmentioning
confidence: 92%
“…One of the strategies used to enhance thermal stability of PPY was synthesis multiwalled carbon nanotubes-PPY composite. Compared to PPY, multiwalled carbon nanotubes-PPY composite showed higher thermal stability and charge delocalization properties [21,22]. Also, the changing of synthesis medium from aqueous to organic medium led to enhance thermal stability of PPY fibers [23].…”
Section: Introductionmentioning
confidence: 92%
“…Compared to those obtained by HPLC (0.15 ng/mL) (Li, Cai, Shi, Mou, & Jiang, 2008); GC-MS (0.10 ng/mL) (Yuan, Liu, Liao, & Chang, 2002); SPME-GC (0.08 ng/mL) (Asadollahzadeh, Noroozian, & Maghsoudi, 2010) and previous immunoassay methods (97 ng/L) (Ius et al, 1993); (200 ng/mL) (Goda et al, 2000), the LOD of this assay (0.01 ng/mL) is lower. In the immunoassay, the sensitivity was expressed by IC 50 value, the lower of the IC 50 value, the higher sensitivity of the assay would be (Wang et al, 2009).…”
Section: Discussionmentioning
confidence: 55%
“…The IC 50 values were calculated to be 17.12, 20.42, 22.28, 47.86, 43.65, 38.9, 102.57 and 64.57 ng mL À1 , and the LODs were 0.013, 0.013, 0.012, 0.042, 0.035, 0.021, 0.017 and 0.016 ng mL À1 for DMP, DEP, DBP, DEHP, DnOP, BBP, DCHP and DNP, respectively. Compared with instrumental analysis, the LOD of DBP in aqueous sample was 0.07 ng mL À1 by gas chromatography separation and ame ionization detection using a solid phase micro-extraction cleanup, 38 while that of DEHP in river surface water was 9.3 ng mL À1 by GC-MS; 39 thus, our method has a higher sensitivity. 22 It can be seen that besides DMP, DnOP and DBP, the other ve PAEs also have lower LODs with the polyclonal antibody prepared in this study.…”
Section: Optimization Of Elisa Conditionsmentioning