2013
DOI: 10.1016/j.jct.2012.09.023
|View full text |Cite
|
Sign up to set email alerts
|

Solubility of CO2 in amide-based Brønsted acidic ionic liquids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 22 publications
(13 citation statements)
references
References 26 publications
0
13
0
Order By: Relevance
“…In these experiments they found that, with the same cation CO 2 solubility in TFA-based BAILs are higher than that in FBA-based ones. 594 Mumford et al recently evaluated the protic ionic liquid ethylenediamine N,N-dimethylaminoethylammonium formate for the removal of CO 2 from N 2 mixed gas streams. 596 This evaluation was conducted by comparison with the industrial standard 30 wt % monoethanolamine (MEA).…”
Section: Carbon Dioxide Dissolution and Fixationmentioning
confidence: 99%
“…In these experiments they found that, with the same cation CO 2 solubility in TFA-based BAILs are higher than that in FBA-based ones. 594 Mumford et al recently evaluated the protic ionic liquid ethylenediamine N,N-dimethylaminoethylammonium formate for the removal of CO 2 from N 2 mixed gas streams. 596 This evaluation was conducted by comparison with the industrial standard 30 wt % monoethanolamine (MEA).…”
Section: Carbon Dioxide Dissolution and Fixationmentioning
confidence: 99%
“…The stainless steel apparatus was an upgraded version, based on our previous glass equipment, 24 as shown in Fig. 1.…”
Section: Apparatusmentioning
confidence: 99%
“…1 and the Experimental procedure was described in detail in our previous works. [39][40][41][42] The apparatus was mainly made up of a SO 2 cylinder, constant temperature water baths with a precision of AE0.05 K, a SO 2 Gas Reservoir (4, GR), Equilibrium Chamber (5, EC) with magnetic stirrer, pressure transmitter and digital indicator. The volumes of EC and GR were measured in our previous reported method 39 with the results of 141.61 cm 3 and 370.99 cm 3 , respectively.…”
Section: Apparatus and Procedures To Determine Solubility Of So 2 In ...mentioning
confidence: 99%
“…[39][40][41][42] The apparatus was mainly made up of a SO 2 cylinder, constant temperature water baths with a precision of AE0.05 K, a SO 2 Gas Reservoir (4, GR), Equilibrium Chamber (5, EC) with magnetic stirrer, pressure transmitter and digital indicator. The volumes of EC and GR were measured in our previous reported method 39 with the results of 141.61 cm 3 and 370.99 cm 3 , respectively. Two pressure transmitters (Fujian WIDEPLUS Precision Instruments Co., Ltd. WIDEPLUS-8) with a precision of AE0.6 kPa were used to record pressure change during absorption process.…”
Section: Apparatus and Procedures To Determine Solubility Of So 2 In ...mentioning
confidence: 99%