2010
DOI: 10.1016/j.fluid.2010.08.027
|View full text |Cite
|
Sign up to set email alerts
|

Solubility of H2S in 1-(2-hydroxyethyl)-3-methylimidazolium ionic liquids with different anions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
67
1

Year Published

2012
2012
2020
2020

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 121 publications
(68 citation statements)
references
References 20 publications
0
67
1
Order By: Relevance
“…The values are lower than the available literature values [25], with the relative deviations ranging from (1.16 to 1.30)% over the above temperature. The measuring method of this paper is the same with the literature [25] by the automated SVM3000 Anton Paar rotational Stabinger viscometer-densimeter. This difference cannot be explained by the densimeter alone and must be the result of the impurities of the sample such as residual water and salts from the synthesis.…”
Section: Resultscontrasting
confidence: 74%
See 1 more Smart Citation
“…The values are lower than the available literature values [25], with the relative deviations ranging from (1.16 to 1.30)% over the above temperature. The measuring method of this paper is the same with the literature [25] by the automated SVM3000 Anton Paar rotational Stabinger viscometer-densimeter. This difference cannot be explained by the densimeter alone and must be the result of the impurities of the sample such as residual water and salts from the synthesis.…”
Section: Resultscontrasting
confidence: 74%
“…From the tables 2 and 3, the value of electrical conductivity is 0.919 mS Á cm À1 for FIL [ [25]. The values are lower than the available literature values [25], with the relative deviations ranging from (1.16 to 1.30)% over the above temperature.…”
Section: Resultsmentioning
confidence: 78%
“…Jalili et al [26] have experimentally studied solubility of carbon dioxide and hydrogen sulfide gases in [emim][EtSO 4 ] and they have used Krichevsky-Kasarnovsky equation for correlating solubility data. Similar studies have been performed by Sakhaeinia et al [27] to measure and model solubility of hydrogen sulfide in different ionic liquids. Palgunadi et al [28] have measured solubility of ethylene and acetylene in ionic liquids and they have used these solvents for acetylene-ethylene separation.…”
Section: Introductionmentioning
confidence: 54%
“…Using the data in table 1 and experimental liquid density of pure ILs[20,[45][46][47][48][49][50][51][52] the parameters of the PR-TS EoS ( 0 a , b , 1 c , ii E and ii  ) for pure components are correlated at a wide range of temperatures and pressures as following objective function…”
mentioning
confidence: 99%