2014
DOI: 10.1007/s10870-014-0506-6
|View full text |Cite
|
Sign up to set email alerts
|

Solution and Solid-State Structure of cis-Dichloro-(N,N′-dimethylethylenediamine)platinum(II)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
6
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
4

Relationship

3
1

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 20 publications
0
6
0
Order By: Relevance
“…NMR spectra were recorded on 300 or 400 MHz instruments. X-ray crystallographic data were obtained on a benchtop single-crystal diffractometer using methods described previously . Infrared absorption spectra were recorded on a Bruker Tensor 27 FTIR using a single reflection ATR accessory with a germanium crystal.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…NMR spectra were recorded on 300 or 400 MHz instruments. X-ray crystallographic data were obtained on a benchtop single-crystal diffractometer using methods described previously . Infrared absorption spectra were recorded on a Bruker Tensor 27 FTIR using a single reflection ATR accessory with a germanium crystal.…”
Section: Methodsmentioning
confidence: 99%
“…X-ray crystallographic data were obtained on a benchtop single-crystal diffractometer using methods described previously. 20 Infrared absorption spectra were recorded on a Bruker Tensor 27 FTIR using a single reflection ATR accessory with a germanium crystal. Thermogravimetric analysis (TGA) experiments were performed on a TA Instruments Q50 analyzer under a nitrogen atmosphere and the samples were heated at a rate of 10 °C/min.…”
mentioning
confidence: 99%
“…The input files were generated with GaussView. X-ray crystallographic data were obtained on a benchtop single-crystal diffractometer using methods described previously …”
Section: Methodsmentioning
confidence: 99%
“…X-ray crystallographic data were obtained on a benchtop single-crystal diffractometer using methods described previously. 17 5-(4-(Diethylamino)phenyl)thiophene-2-carbaldehyde (3). A N 2 -purged Schlenk flask containing 4-(diethylamino)phenylboronic acid (1.21 g, 6.28 mmol), 5bromothiophene-2-carbaldehyde (1.0 g, 5.23 mmol), Pd-(PPh 3 ) 4 (0.30 g, 0.26 mmol), K 2 CO 3 (2.16 g, 15.69 mmol), and THF/water 30 mL (1:1) was equipped with a magnetic stir bar and a reflux condenser and heated at 90 °C for 24 h. The reaction mixture was then poured into water and extracted with CH 2 Cl 2 (4 × 150 mL).…”
Section: ■ Methodsmentioning
confidence: 99%
“…Mass spectra were obtained on an EI mass spectrometer using a direct insertion probe. X-ray crystallographic data were obtained on a benchtop single-crystal diffractometer using methods described previously …”
Section: Methodsmentioning
confidence: 99%