2023
DOI: 10.3390/coatings13020425
|View full text |Cite
|
Sign up to set email alerts
|

Solvent Effect on Small-Molecule Thin Film Formation Deposited Using the Doctor Blade Technique

Abstract: Small molecule thin films are the core of some organic optoelectronic devices. Their deposition by solution processes is an advantage for device fabrication and can be achieved via spin coating for small areas and slot-die or doctor blade for larger areas. Solution deposition of small molecule thin films is usually processed only with medium polarity solvents. Herein, the use and influence of solvents with several polarities and physicochemical properties to form small-molecule homogeneous thin films via the d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 29 publications
0
1
0
Order By: Relevance
“…The first step was to demonstrate the fabrication of MN from the dendritic triblock amphiphile. As a starting point, ethanol and chloroform were used to cast the Tri-C9 polymer; however, aggregates were formed instead of a homogeneous MN array (Figure S2); this is attributed to the swift solvent evaporation rate and the fragility of the polymer film, wherein the polymer chains have limited opportunities to entangle, hindering the formation of a stable film layer on the MN mold . Consequently, poly­(vinyl pyrrolidone) (PVP) was incorporated into the polymeric solution in ethanol, due to its film-strengthening ability. , Upon drying, the MN array was detachable, yet the resultant MNs showed poorly defined shape, nonhomogeneous spreading of the polymer, and incomplete filling of the MN mold cavities (Figure S3).…”
Section: Resultsmentioning
confidence: 99%
“…The first step was to demonstrate the fabrication of MN from the dendritic triblock amphiphile. As a starting point, ethanol and chloroform were used to cast the Tri-C9 polymer; however, aggregates were formed instead of a homogeneous MN array (Figure S2); this is attributed to the swift solvent evaporation rate and the fragility of the polymer film, wherein the polymer chains have limited opportunities to entangle, hindering the formation of a stable film layer on the MN mold . Consequently, poly­(vinyl pyrrolidone) (PVP) was incorporated into the polymeric solution in ethanol, due to its film-strengthening ability. , Upon drying, the MN array was detachable, yet the resultant MNs showed poorly defined shape, nonhomogeneous spreading of the polymer, and incomplete filling of the MN mold cavities (Figure S3).…”
Section: Resultsmentioning
confidence: 99%