2015
DOI: 10.1515/geochr-2015-0024
|View full text |Cite
|
Sign up to set email alerts
|

Some considerations in the reconstruction of lead levels using laser ablation: lessons from the design stage of dendrochemistry study, St.John's, Canada

Abstract: Study of soils in St. John's, Canada showed elevated Pb levels representing a potential exposure risk for young children. Old trees growing in the city present a potential annually-resolved record of Pb levels over past centuries that provides important temporal and spatial dimensions to Pb exposure risk assessment. This paper reports the results of our analytical tests to develop a fast, reliable and cost-efficient method using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for measur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(20 citation statements)
references
References 61 publications
0
20
0
Order By: Relevance
“…One challenge with LA-ICPMS line scans is the lack of a standardized method for aligning the microchemistry results with post-ablation visual landmarks -such as otolith daily growth rings (Danek et al 2015). To address this, we used inflections in the calcium signatures to identify the otolith edges on the microchemistry scan and calculated the actual scan rate as the otolith scan time (using these edges) divided by the measured width of the otolith along the laser transect (Andrew Claiborne, Washington Department of Fisheries, Washington, personal communication, 2018).…”
Section: Otolith Analysesmentioning
confidence: 99%
“…One challenge with LA-ICPMS line scans is the lack of a standardized method for aligning the microchemistry results with post-ablation visual landmarks -such as otolith daily growth rings (Danek et al 2015). To address this, we used inflections in the calcium signatures to identify the otolith edges on the microchemistry scan and calculated the actual scan rate as the otolith scan time (using these edges) divided by the measured width of the otolith along the laser transect (Andrew Claiborne, Washington Department of Fisheries, Washington, personal communication, 2018).…”
Section: Otolith Analysesmentioning
confidence: 99%
“…In April 2018 tree cores were cut using a microtome (Gärtner and Nievergelt 2010) for dendrochemical analysis. In details, tree cores were not sanded, as usually done in dendrochronology, to avoid the contamination effect due to wood dust (Danek et al 2015). The tree-ring width was measured using the LINTAB instrument (Rinntech, Heidelberg, Germany) and a Leica MS5 stereoscope (Leica Microsystems, Germany).…”
Section: Tree-ring Analysismentioning
confidence: 99%
“…The analysis of chemical elements was performed on annual tree rings from 1990 to 2016 using the laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) (Danek et al 2015;Perone et al 2018). Only one of the two cores collected from each tree was used in this analysis.…”
Section: Dendrochemistry Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…The actual wood sample was considered for data collection when the target value ( 208 Pb: 50,000 cps) was reached. Laser ablation was performed in line scan mode [23]. The ICP-MS set-up and other parameters are provided in Table 2.…”
Section: Experimental Conditions Of La-icp/msmentioning
confidence: 99%