2007
DOI: 10.1007/s00330-007-0771-2
|View full text |Cite
|
Sign up to set email alerts
|

Sonography of the finger flexor and extensor system at the hand and wrist level: findings in volunteers and anatomical correlation in cadavers

Abstract: We present a review of sonography of the flexor and extensor system of the hand and wrist in volunteers and cadavers. CT tenography also was performed in cadaveric specimens. Anatomical structures of the extensor system that were assessed with sonography included the extensor tendons and insertions, retinaculum, and dorsal hood. On the flexor side, the variable relationship between the flexor superficialis and profundus could be appreciated. Volar plates, tendon insertions, and annular pulleys could also be in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
12
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 15 publications
(12 citation statements)
references
References 16 publications
0
12
0
Order By: Relevance
“…However, we do not have a comparison of CEUS and PDUS in healthy tendons, but in previous studies, using CEUS, entheses are described as nonvascularized areas in healthy controls [17,32]. Furthermore, the peritendinous space within normal tendon sheaths is considered to be nonvascularized [33]. Nevertheless, further studies are required to assess normal tendons regarding potential intratendinous vascularity detectable with CEUS.…”
Section: Discussionmentioning
confidence: 99%
“…However, we do not have a comparison of CEUS and PDUS in healthy tendons, but in previous studies, using CEUS, entheses are described as nonvascularized areas in healthy controls [17,32]. Furthermore, the peritendinous space within normal tendon sheaths is considered to be nonvascularized [33]. Nevertheless, further studies are required to assess normal tendons regarding potential intratendinous vascularity detectable with CEUS.…”
Section: Discussionmentioning
confidence: 99%
“…Because some structures were only visible in larger patients, we hypothesize that the smaller structures may become increasingly difficult to image in smaller patients. High‐frequency probes (>13 MHz) used for examination of musculoskeletal structures of the human extremity 10 may lead to better resolution in smaller dogs.…”
Section: Discussionmentioning
confidence: 99%
“…Normal finger extensor tendons appeared as slightly hyperechoic thin fiber bundles in longitudinal and transverse planes on ultrasonography 9 , 10 . As shown in Fig.…”
Section: Resultsmentioning
confidence: 99%