2020
DOI: 10.1007/s11270-020-4403-7
|View full text |Cite
|
Sign up to set email alerts
|

Sorbent Materials Characterization Based on Mechanical or Thermal Pretreated Montmorillonite Modified by Surfactant Loading for Improved Chromium Retention

Abstract: To improve hexavalent chromium (Cr(VI)) retention of montmorillonite (Mt) at pH 3, Mt sample was subjected to different treatments: thermal ones at 600 °C or 950 °C, 2 h, or mechanical grinding for 300 s. Then, the obtained products were loaded with different octadecyl trimethyl ammonium loading and 50% and 100% of Mt cation exchange capacity (CEC). The samples were characterized by several techniques at each stage. Differential thermogravimetric analysis (DTGA) performed on the products allowed determining th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 51 publications
0
5
0
Order By: Relevance
“…Total chromium (Cr Total ) concentration in solution was measured by using a flame atomic absorption spectrometer (FAAS) (Sens AA dual GBC Scientific Equipment). The difference between Cr Total and Cr­(VI) was considered as Cr­(III) . Unless otherwise indicated, all data shown are the mean values from two replicate experiments.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…Total chromium (Cr Total ) concentration in solution was measured by using a flame atomic absorption spectrometer (FAAS) (Sens AA dual GBC Scientific Equipment). The difference between Cr Total and Cr­(VI) was considered as Cr­(III) . Unless otherwise indicated, all data shown are the mean values from two replicate experiments.…”
Section: Methodsmentioning
confidence: 99%
“…The difference between Cr Total and Cr(VI) was considered as Cr(III). 7 Unless otherwise indicated, all data shown are the mean values from two replicate experiments. The typical experimental error was less than 5% for all results.…”
Section: Industrial and Engineeringmentioning
confidence: 99%
See 2 more Smart Citations
“…Also, MMT and its modified forms were used to adsorb the sulfamethoxazole and tetracycline, 18 chromium(IV) retention, 19 cationic dyes, 20 tetracycline antibiotics, 21 acid Red 17, 22 calcium ion and bisphenol A, 23 bisphenol A, 24 rhodamine and hexavalent chromium, 25 thiabendazole, 26 and soil humic acid. 27 In this study, the effects of MMT and its modified forms with the chlorosulfonic acid (SMMT) were evaluated for the adsorption of the THMs.…”
Section: Introductionmentioning
confidence: 99%