2020
DOI: 10.3390/s20113302
|View full text |Cite
|
Sign up to set email alerts
|

Source–Detector Spectral Pairing-Related Inaccuracies in Pulse Oximetry: Evaluation of the Wavelength Shift

Abstract: Pulse oximetry enables oxygen saturation estimation ( S p O 2) non-invasively in real time with few components and modest processing power. With the advent of affordable development kits dedicated to the monitoring of biosignals, capabilities once reserved to hospitals and high-end research laboratories are becoming accessible for rapid prototyping. While one may think that medical-grade equipment differs greatly in quality, surprisingly, we found that the performance requirements are not widely different… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 34 publications
0
8
0
Order By: Relevance
“…Then, the P_R and P_IR subblocks are used to convert the output current i R of LHQ974o and SFH4080o into luminous intensity in Watt. The actual spectral distribution of both LEDs is usually modeled by a Gaussian curve (Tsiakaka, et al, 2020) and the total radiant flux is the integral of the entire spectrum.…”
Section: Ledmentioning
confidence: 99%
See 3 more Smart Citations
“…Then, the P_R and P_IR subblocks are used to convert the output current i R of LHQ974o and SFH4080o into luminous intensity in Watt. The actual spectral distribution of both LEDs is usually modeled by a Gaussian curve (Tsiakaka, et al, 2020) and the total radiant flux is the integral of the entire spectrum.…”
Section: Ledmentioning
confidence: 99%
“…The second step is to validate the whole system by comparing our simulation data with previous results (Tsiakaka, et al, 2020), where authors used six different pairs of red/IR LED to plot six SpO 2 -R OS curves. We were able to measure these LEDs optical and electrical characteristics, in order to simulate these devices with our developed model.…”
Section: Models Validationmentioning
confidence: 99%
See 2 more Smart Citations
“…Because of the advancement of technology and research, such as spectrophotometry, opt acoustic and transmission spectroscopy, many low-cost and simple non-invasive technologies have emerged. Several researchers had discussed the uses of multi-wavelength pulse oximeters to detect hemoglobin levels, and SpO 2 (29)(30)(31)(32) . Macknet et al evaluated Hb measurement with hemodilution and compared it with pulse CO-Oximeters and invasive laboratory CO-Oximeter Hb measurements which were carried out in both healthy and surgical subjects (33) .…”
Section: Introductionmentioning
confidence: 99%