2006
DOI: 10.1063/1.2216987
|View full text |Cite
|
Sign up to set email alerts
|

Spatial distribution measurement of atomic radiation with an astigmatism-corrected Czerny-Turner-type spectrometer in the Large Helical Device

Abstract: Emission lines in the visible/UV wavelength ranges are observed with 80 lines of sight which cover an entire poloidal cross section of the plasma in the Large Helical Device. The emitted light is received with optical fibers having 100 m diameter and is guided into a 1.33 m Czerny-Turner-type spectrometer based on spherical mirrors for collimating and focusing. A charge-coupled device having 13.3ϫ 13.3 mm 2 area size is used as the detector and the spectra from all the lines of sight are recorded perpendicular… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
19
0
1

Year Published

2007
2007
2020
2020

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 29 publications
(22 citation statements)
references
References 8 publications
2
19
0
1
Order By: Relevance
“…Distribution of the plasma source in Fig. 4(c) reflects those processes and consistent with observation of H α radiation [12]. • with open divertor configuration.…”
Section: Simulation Results and Discussionsupporting
confidence: 80%
“…Distribution of the plasma source in Fig. 4(c) reflects those processes and consistent with observation of H α radiation [12]. • with open divertor configuration.…”
Section: Simulation Results and Discussionsupporting
confidence: 80%
“…16. ͑Color online͒ ͑a͒ Chord-integrated bremsstrahlung intensity, ͑b͒ bremsstrahlung emissivity after Abel inversion for two different fitting curves, ͑c͒ normalized errors of intensity ͑solid circles͒, Err I = ͑I fit1 -I fit2 ͒ / I fit1 , and emissivity ͑open circles͒, Err = ͑ fit1 -fit2 ͒ / fit1 , between two fitting profiles.…”
Section: Analysis Of Z Eff Profilementioning
confidence: 99%
“…La óptica externa forma imagen de una escena sobre la rendija de entrada del sistema dispersivo que separa el espectro de la luz proveniente de dicha rendija en ángulos diferentes en función de su longitud de onda en una dirección perpendicular a la misma y forma imagen sobre la unidad de detención. Entre algunos de los sistemas estudiados y utilizados como unidad dispersiva en un sensor hiperespectral tipo pushbroom, se pueden destacar el sistema Offner [13][14][15][16], el sistema Dyson [17,18], los sistemas PGP (Prism-Grating-Prism) [19,20] o modificaciones del sistema Czerny-Turner [21,22]. Fig.2.…”
Section: A Espectrómetros De Imagen Dispersivos Tipo Pushbroom: Siunclassified