2015
DOI: 10.1039/c5ay00555h
|View full text |Cite
|
Sign up to set email alerts
|

Speciation and quantification of organotin compounds in sediment and drinking water by isotope dilution liquid chromatography-inductively coupled plasma-mass spectrometry

Abstract: A rapid method was developed for the determination of monobutyltin, dibutyltin, tributyltin, monophenyltin, diphenyltin, and triphenyltin by liquid chromatography-isotope dilution-inductively coupled plasma-mass spectrometry in sediments and drinking water. All six species were eluted in less than 6.5 minutes with a binary gradient. Offline solid phase extraction was used to pre-concentrate the organotin compounds for quantification employing two calibration procedures; external standard calibration and isotop… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 44 publications
0
4
0
Order By: Relevance
“…208 All six species were eluted in less than 6.5 min with a binary gradient. Although the determination of OTCs in sea water and seafood products continues to be reported, most studies use well established techniques such as HPLC-ICP-MS. Other workers employ techniques which are strictly outside the scope of this review, although some may be of interest to those working in this area.…”
Section: Tinmentioning
confidence: 99%
See 1 more Smart Citation
“…208 All six species were eluted in less than 6.5 min with a binary gradient. Although the determination of OTCs in sea water and seafood products continues to be reported, most studies use well established techniques such as HPLC-ICP-MS. Other workers employ techniques which are strictly outside the scope of this review, although some may be of interest to those working in this area.…”
Section: Tinmentioning
confidence: 99%
“…One example is the The speciation and quantication of the same OTCs (MBT, DBT, TBT, MPhT, DPhT and TPhT) in sediment and drinking water by ID-HPLC-ICP-MS has been reported. 208 All six species were eluted in less than 6.5 min with a binary gradient. Offline SPE was used to pre-concentrate the organotin compounds for quantication employing two calibration procedures; external standard calibration and isotopic dilution.…”
Section: Tinmentioning
confidence: 99%
“…As an alternative, liquid chromatography (LC) methods provide simple and rapid techniques for analysis of OTCs in diverse forms of environmental samples. The use of LC in conjunction with inductively coupled plasma mass spectrometry detection (ICP‐MS) and fluorescence detection has been reported. Because ICP‐MS is only an element‐specific detector, it cannot provide the information required to characterize or confirm specific OTC species, although good sensitivity is obtained.…”
Section: Introductionmentioning
confidence: 99%
“…One method is inductively coupled plasma mass spectrometry (ICP-MS), which has high sensitivity, low detection limits, and is capable of simultaneous multi-element analysis. [8][9][10][11][12][13][14][15][16][17][18][19] However, isobaric and/or polyatomic interferences derived from the presence of high concentrations of matrix elements are signicant limitations of this technology. 20 All isotopes of Cd are subject to interferences from various isobaric ions and/or oxide or hydroxide ions of Pd, Sn, In, Zr, Mo, Ru, Nb, and Y.…”
Section: Introductionmentioning
confidence: 99%