1984
DOI: 10.1007/bf00697636
|View full text |Cite
|
Sign up to set email alerts
|

Speciation of actinide ions in aqueous solution by laser-induced pulsed photoacoustic spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
17
0

Year Published

1985
1985
2021
2021

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 53 publications
(18 citation statements)
references
References 8 publications
1
17
0
Order By: Relevance
“…The whole spectroscopic operation is automated. Background signals are compensated by a differential method measuring sample and reference solutions at the same time by two identical detection cells in a tandem alignment [5]. The compensation is not always perfect, since both cuvettes as well as both piezodetectors are not absolutely identical and in addition the laser power is slightly lowered in the second cell.…”
Section: Methodsmentioning
confidence: 99%
“…The whole spectroscopic operation is automated. Background signals are compensated by a differential method measuring sample and reference solutions at the same time by two identical detection cells in a tandem alignment [5]. The compensation is not always perfect, since both cuvettes as well as both piezodetectors are not absolutely identical and in addition the laser power is slightly lowered in the second cell.…”
Section: Methodsmentioning
confidence: 99%
“…This work builds on the LPAS studies carried out by PATEL and ΤΑΜ [2] who first demonstrated high LPAS sensitivity in aqueous solution using microsecond excitation [3]and on actinide LPAS studies carried out by KIM and coworkers [4,5,6,7] who demonstrated high LPAS sensitivity at ambient temperature using nanosecond excitation. A significant advance reported here is achievement of high LPAS sensitivity at 90°C in carrying out speciation studies of Am 3+ in a carbonate solution.…”
Section: Introductionmentioning
confidence: 98%
“…The observed increase in wavelength of the absorption peak with increased carbonate concentration, at a fixed pH, as shown in Table 1, is reflected in the predicted increase in the number of carbonate ions complexed with an americium ion as indicated in Table 2. The formation of mixed hydroxyl/carbonate complexes is confirmed by the increase in peak wavelength [0][1][2][3][4][5] with increased pH at a fixed carbonate concentration again indicated in Table 1. The highest peak wavelength observed was 507.8 nm, shown in Figure 4, for a solution at pH 11.5 and 1 M in CO3 " (Table 1), and is probably associated with the presence of Am (OH) (CO 3)2 ~ ( Table 2).…”
Section: Americium Speciationmentioning
confidence: 62%
“…'Direct' methods are essentially non-invasive causing minimal disturbance of species equilibria, and are consequently more reliable though less sensitive. A survey of speciation methods [1] identified laser induced photoacoustic spectroscopy, LIPAS, as a highly sensitive 'direct' method capable of measuring actinide spectra down to ca 10" 8 M [2][3][4][5][6] and hence providing information on oxidation states and complexation. Consequently, it was selected at the Harwell Laboratory for further development and installation as the principal 'direct' speciation method.…”
Section: Introductionmentioning
confidence: 99%