2002
DOI: 10.3358/shokueishi.43.348
|View full text |Cite
|
Sign up to set email alerts
|

Specific Determination of Bromate in Bread by Ion Chromatography with ICP-MS.

Abstract: A sensitive method for detecting bromate in bread by ion chromatography with inductivelycoupled plasma mass spectrometry (IC/ICP-MS) was developed. Bromate was extracted from bread with water. The clean-up procedure included a 0.2 mm filter, a C 18 cartridge for defatting, a silver cartridge to remove halogen anions, a centrifugal ultrafiltration unit to remove proteins, and a cation-exchange cartridge to remove silver ions. A 500 mL sample solution was applied to IC/ ICP-MS. The detection limit and the quanti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
2
0

Year Published

2003
2003
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 10 publications
1
2
0
Order By: Relevance
“…The mean content of KBrO 3 (Table 2) found in the samples collected in bakeries A, B, C, D, and E were 6.29±0. The concentration of KBrO 3 in bread samples obtained in this study is similar to the 3.60 and 9.20 μg/g for the lowest and highest level of KBrO 3 as reported in Gwagwalada, Nigeria [11].It is also similar to 3.70 and 12.10 μg/g as the lowest and highest level of KBrO 3 found in bread samples consumed in Kaduna metropolis respectively [23]. The concentration of KBrO 3 in bread samples obtained in this study was above the USFDA permissible limit, which is an indication that the brands of bread samples are unsafe for human consumption.…”
Section: 5supporting
confidence: 87%
See 1 more Smart Citation
“…The mean content of KBrO 3 (Table 2) found in the samples collected in bakeries A, B, C, D, and E were 6.29±0. The concentration of KBrO 3 in bread samples obtained in this study is similar to the 3.60 and 9.20 μg/g for the lowest and highest level of KBrO 3 as reported in Gwagwalada, Nigeria [11].It is also similar to 3.70 and 12.10 μg/g as the lowest and highest level of KBrO 3 found in bread samples consumed in Kaduna metropolis respectively [23]. The concentration of KBrO 3 in bread samples obtained in this study was above the USFDA permissible limit, which is an indication that the brands of bread samples are unsafe for human consumption.…”
Section: 5supporting
confidence: 87%
“…Several analytical techniques had been developed for the quantitative determination of KBrO 3 in bread which involve the use of sophisticated and expensive equipment. They include: Ion chromatography method with ICP-MS [10,11], Redox titrimetric method [12], High Performance Liquid Chromatography [13,14], and spectroscopic methods [15,16,17]. However, there are several limitations associated with many of these currently available methods, such as being time consuming and requiring complicated instrumentation.…”
Section: Introductionmentioning
confidence: 99%
“…An LOD of 0.4 mg g 21 was reported for a 30 mg dry sample and the method was validated by analysing TORT-1 CRM. To determine BrO 3 2 Akiyama et al 219 developed an unusually prolonged procedure that included extraction with water, a 0.2 mm filter and thenx removal of fat, halide anions and protein with a C 18 cartridge, a silver cartridge and centrifugal ultracentrifugation, Mg concentrations were determined by ICP-MS. 25 Mg enrichments in blood cells from Mg-deficient rats were greater than those from controls. In humans, 25 , SeMet, SeEt and TmSe) by gel-permeation chromatography and ICP-MS was developed.…”
Section: Sampling and Sample Preparationmentioning
confidence: 99%