Spectral Optical Readout of Rectangular–Miniature Hollow Glass Tubing for Refractive Index Sensing

Abstract: For answering the growing demand of innovative micro-fluidic devices able to measure the refractive index of samples in extremely low volumes, this paper presents an overview of the performances of a micro-opto-fluidic sensing platform that employs rectangular, miniature hollow glass tubings. The operating principle is described by showing the analytical model of the tubing, obtained as superposition of different optical cavities, and the optical readout method based on spectral reflectivity detection. We have… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
4
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 40 publications
1
4
0
Order By: Relevance
“…The capillary spectral reflectivity is characterized by minima at wavelengths corresponding to the optical resonances of the multilayer structure. The wavelength positions of resonances depend on the thickness of the layers and, in particular, on the RI of the liquid contained in the channel, as demonstrated in previous work [15][16][17]. Moreover, as shown in Figure 2a, the overall spectrum shifts towards higher wavelengths when the sample RI increases from water (black trace) to saline solution (red trace).…”
Section: Theoretical Resultssupporting
confidence: 71%
See 3 more Smart Citations
“…The capillary spectral reflectivity is characterized by minima at wavelengths corresponding to the optical resonances of the multilayer structure. The wavelength positions of resonances depend on the thickness of the layers and, in particular, on the RI of the liquid contained in the channel, as demonstrated in previous work [15][16][17]. Moreover, as shown in Figure 2a, the overall spectrum shifts towards higher wavelengths when the sample RI increases from water (black trace) to saline solution (red trace).…”
Section: Theoretical Resultssupporting
confidence: 71%
“…Considering a sensitivity of the order of 360 nm/RIU, previously calculated from the experimental results attained with water and saline solutions, when substituting ethanol with isopropanol we expect a spectral shift of the order of 5 nm-almost as large as the typical wavelength separation between consecutive minima relative to resonances of the same order. Note that it was already demonstrated in previous works [17] that the separation between consecutive minima differs from one to another. This second set of experiments was performed to demonstrate that phase-sensitive detection was feasible, and also suitable, for large RI variations, close to the limit of the unambiguous range.…”
Section: Resultsmentioning
confidence: 62%
See 2 more Smart Citations
“…Furthermore, they strongly reduce the light scattering that arises when using round-section capillaries. In previous works, we exploited rectangular glass microcapillaries with channel depths of the order of few tenths of a nanometer to measure the real part of the refractive index (RI) of liquids and its variations with respect to a reference sample, either by exploiting the detection of the spectral resonances of these devices, which can be seen as optical resonators [14][15][16], or by inserting them into a Michelson scheme and performing interferometric measurements [17,18]. However, these kinds of analyses are non-specific since the same RI change can be produced by different substances present in the solution.…”
Section: Introductionmentioning
confidence: 99%