Spectrally accurate quantitative analysis of isotope‐labeled compounds

Abstract: Calculated profile mode mass spectrometry (MS) data are fitted to lineshape‐calibrated liquid chromatography LC/MS data using a Multiple Linear Regression (MLR) model to quantitate the relative concentrations of stable or radiolabeled compound mixtures. This alternative approach significantly improves the precision and accuracy over existing MS methods while providing the much‐needed statistical diagnostics on the goodness‐of‐fit model and thus reliability of the quantitative results obtained. Test compound da… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 21 publications
0
2
0
Order By: Relevance
“…In our current study, the conditions we used for analyzing the lipids were not sufficient to detect cholesterol, a major myelin constituent, which is usually cationized via alkaline hydrolysis and detected, for example, as ammoniated, lithiated, or sodiated adducts ( West and Reid, 2021 ). Spectral accuracy of our original data was determined using MassWorks (Version 6,0,0,0) software from Cerno Bioscience (LasVegas, NV 89144) ( Wang and Gu, 2010 ; Kuehl et al., 2021 ). (The MassWorks software also corrected automatically for the presence in the deuterated lipids of the natural isotope abundance that was detected in the non-deuterated samples (H-dam and H-pup spectra, see below).…”
Section: Mass Spectrometrymentioning
confidence: 99%
“…In our current study, the conditions we used for analyzing the lipids were not sufficient to detect cholesterol, a major myelin constituent, which is usually cationized via alkaline hydrolysis and detected, for example, as ammoniated, lithiated, or sodiated adducts ( West and Reid, 2021 ). Spectral accuracy of our original data was determined using MassWorks (Version 6,0,0,0) software from Cerno Bioscience (LasVegas, NV 89144) ( Wang and Gu, 2010 ; Kuehl et al., 2021 ). (The MassWorks software also corrected automatically for the presence in the deuterated lipids of the natural isotope abundance that was detected in the non-deuterated samples (H-dam and H-pup spectra, see below).…”
Section: Mass Spectrometrymentioning
confidence: 99%
“…In our current study, the conditions we used for analyzing the lipids were not sufficient to detect cholesterol, a major myelin constituent, which is usually cationized via alkaline hydrolysis and detected, for example, as ammoniated, lithiated, or sodiated adducts [33]. Spectral accuracy of our original data was determined using MassWorks (Version 6,0,0,0) software from Cerno Bioscience (LasVegas, NV 89144) [34,35]. (The MassWorks software also corrected automatically for the presence in the deuterated lipids of the natural isotope abundance that was detected in the non-deuterated samples (H-dam and H-pup spectra, see below).…”
Section: Lipid Analysis By Mass Spectrometrymentioning
confidence: 99%