Spectrofluorimetric determination of anthranilic acid derivatives based on terbium sensitized fluorescence

Abstract: Terbium sensitized fluorescence was used to develop a sensitive and simple spectrofluorimetric method for the determination of the anthranilic acid derivatives furosemide and mefenamic and tolfenamic acids. The method makes use of radiative energy transfer from anthranilates to terbium ions in alkaline methanolic solutions. Optimum conditions for the formation of the anthranilate-Tb3+ complexes were investigated. Under optimized conditions, the detection limits are 6 x 10(-9), 1.4 x 10(-8) and 9.0 x 10(-9) mol… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
34
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 65 publications
(35 citation statements)
references
References 28 publications
0
34
0
Order By: Relevance
“…21,61,62 In serum and urine, furosemide is the predominant species. 21,61 Taking into account the role of the 4-chloro-N-furfuryl-5-sulphamoyl-anthranilate ion (Fur) in the electrode response, along with the low concentration of acyl glucuronides in serum and urine, 21,61 no interference from these metabolites is expected in the determination of HFur in urine and human blood serum by the proposed sensor.…”
Section: Analytical Applicationmentioning
confidence: 99%
See 2 more Smart Citations
“…21,61,62 In serum and urine, furosemide is the predominant species. 21,61 Taking into account the role of the 4-chloro-N-furfuryl-5-sulphamoyl-anthranilate ion (Fur) in the electrode response, along with the low concentration of acyl glucuronides in serum and urine, 21,61 no interference from these metabolites is expected in the determination of HFur in urine and human blood serum by the proposed sensor.…”
Section: Analytical Applicationmentioning
confidence: 99%
“…The amounts of HFur added to each biological fluid (urine and human blood serum) were those usually found after administration of a pharmaceutical dose. 21,28,[30][31][32]63,64 Commercial skimmed milk samples were spiked with HFur at a concentration level of 150 ng mL -1 and treated following the procedure described under "Determination of Furosemide in Commercial Milk Samples". This aforementioned concentration is the mean concentration of diurethic that can be detected in the next 8 h after administration of the usual 500 mg dosage of drug.…”
Section: Analytical Applicationmentioning
confidence: 99%
See 1 more Smart Citation
“…47 In humans, FFA is mainly metabolized into acyl glucuronides. [48][49][50] Taking into account the role of the flufenamate ion in the electrode response, along with the very low concentration of glucuronides in serum, 49,50 no interference from these metabolites is expected in the determination of FFA in human blood serum by the proposed electrode.…”
Section: Analytical Applicationmentioning
confidence: 99%
“…47 In humans, FFA is mainly metabolized into acyl glucuronides. [48][49][50] Taking into account the role of the flufenamate ion in the electrode response, along with the very low concentration of glucuronides in serum, 49,50 no interference from these metabolites is expected in the determination of FFA in human blood serum by the proposed electrode.Experiments were performed to determine the feasibility of using the flufenamate-sensitive electrode for determination of FFA in human serum samples. Serum samples previously spiked with 4, 8, 12, 16 and 20 µg mL -1 of FFA were treated and analyzed as described under "Determination of Flufenamic Acid in Human Serum Samples".…”
mentioning