“…This was not observed in the batch method [30], thus indicating that filter paper could be a possible source of interference. It was hypothesised that this background colour could be associated with the presence of aldehyde groups on the filter paper that have been produced as a result of aerial cellulose oxidation [35,36].…”
Section: Preliminary Experiments With the 3-layer µ µ µ µPad Configurmentioning
confidence: 59%
“…Previous studies by Sawicki et al [32] and Barary et al [30] have shown that a Step 2). Error bars are ± standard deviation for 1 σ n-1 (n = 11).…”
Section: Reagent Ratio and Concentrationsmentioning
confidence: 93%
“…The accuracy of the µPAD was determined by recovery experiments which were conducted using spiked saliva samples and the results were compared with those produced by the standard reference method [30] (Table 2). Initial recovery studies using a separate µPAD for the blank (n=11) gave recoveries of 71 -118%.…”
Section: Analysis Of Saliva Samplesmentioning
confidence: 99%
“…In the analytical procedure for the standard reference method [30] 0.5 mL of a standard or sample were first added to 1 mL of MBTH solution. After 20 min, 1 mL of the Fe(III) solution was added to the solution mixture and left to react for a further 10 min.…”
“…The oxidizing agent, which consisted of 160 mM FeCl 3 was prepared by dissolving 216 mg FeCl 3 (SigmaAldrich) in 5 mL of 0.005 M HCl (Ajax FineChem). A 1.85 mM MBTH solution in 0.1 M hydrochloric acid and a 3.70 mM FeCl 3 solution wereused in conducting the spectrophotometric standard reference method[30].…”
“…This was not observed in the batch method [30], thus indicating that filter paper could be a possible source of interference. It was hypothesised that this background colour could be associated with the presence of aldehyde groups on the filter paper that have been produced as a result of aerial cellulose oxidation [35,36].…”
Section: Preliminary Experiments With the 3-layer µ µ µ µPad Configurmentioning
confidence: 59%
“…Previous studies by Sawicki et al [32] and Barary et al [30] have shown that a Step 2). Error bars are ± standard deviation for 1 σ n-1 (n = 11).…”
Section: Reagent Ratio and Concentrationsmentioning
confidence: 93%
“…The accuracy of the µPAD was determined by recovery experiments which were conducted using spiked saliva samples and the results were compared with those produced by the standard reference method [30] (Table 2). Initial recovery studies using a separate µPAD for the blank (n=11) gave recoveries of 71 -118%.…”
Section: Analysis Of Saliva Samplesmentioning
confidence: 99%
“…In the analytical procedure for the standard reference method [30] 0.5 mL of a standard or sample were first added to 1 mL of MBTH solution. After 20 min, 1 mL of the Fe(III) solution was added to the solution mixture and left to react for a further 10 min.…”
“…The oxidizing agent, which consisted of 160 mM FeCl 3 was prepared by dissolving 216 mg FeCl 3 (SigmaAldrich) in 5 mL of 0.005 M HCl (Ajax FineChem). A 1.85 mM MBTH solution in 0.1 M hydrochloric acid and a 3.70 mM FeCl 3 solution wereused in conducting the spectrophotometric standard reference method[30].…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.