2021
DOI: 10.24843/jchem.2021.v15.i01.p10
|View full text |Cite
|
Sign up to set email alerts
|

Spectrophotometric Determination of Boron in Food Products by Ester Borate Distillation Into Curcumin

Abstract: Spectrophotometric determination of boron in food products by ester borate distillation into curcumin was studied. The sensitivity and selectivity of curcumin method were overcome by generating ester borate at proper temperature, time and pH. Boron was separated as triethyl borate by distillation in a vessel using ethanol solvent and reacted with curcumin. Distillation system reached optimum condition at temperature of 75oC and pH 5-6. Boron-curcumin complex was measured at 555 nm after 10 minutes of reaction.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 11 publications
(12 reference statements)
0
2
0
Order By: Relevance
“…The ICP-OES with the gravimetric method has good accuracy for low, medium, and high measurement levels. Based on the data in Table 6 shows that the ICP-OES method has a high accuracy [10], [13] as the AAS [5]; UV-Vis spectrophotometry [8]; and ICP-MS [10]. Based on the precision values obtained and the previous research data presented in Table 6 and the acceptability requirements of the accuracy range, it is a critical aspect in reviewing the selection of boron analysis methods with ICP-OES.…”
Section: Determination Of Accuracymentioning
confidence: 99%
See 1 more Smart Citation
“…The ICP-OES with the gravimetric method has good accuracy for low, medium, and high measurement levels. Based on the data in Table 6 shows that the ICP-OES method has a high accuracy [10], [13] as the AAS [5]; UV-Vis spectrophotometry [8]; and ICP-MS [10]. Based on the precision values obtained and the previous research data presented in Table 6 and the acceptability requirements of the accuracy range, it is a critical aspect in reviewing the selection of boron analysis methods with ICP-OES.…”
Section: Determination Of Accuracymentioning
confidence: 99%
“…These tests require methods that can detect at low concentrations with high precision and accuracy. The determination of boron can be carried out by the method of atomic absorption spectroscopy (AAS) [4]- [6]; UV-Vis spectrophotometer [4], [7], [8]; inductively coupled plasma-optical emission spectrometry (ICP-OES) [4], [9], [10]; inductively coupled plasma mass spectrometry (ICP-MS) [4], [9], [10], inductively coupled plasma atomic emission spectroscopy (ICP-AES) [11], [12] and microwave plasma atomic emission spectrometry (MP-AES) [6].…”
Section: Introductionmentioning
confidence: 99%