1994
DOI: 10.1080/00032719408006392
|View full text |Cite
|
Sign up to set email alerts
|

Spectrophotometric Determination of Lead by Extraction of the Mixed-Metal Complex Pb(II)-Ca-Purpurin (1,2,4-Trihydroxyanthraquinone)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
4
0

Year Published

1999
1999
2017
2017

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 5 publications
0
4
0
Order By: Relevance
“…It is rapid compared with the previously reported procedures for the separation and determination of lead; [8][9][10][11] the time taken for the separation and analysis of lead in a 500-cm 3 water sample is at most 35 min. The LOD of the method (75 ng per 1000 cm 3 ) is improved by a factor of 67, as it compared with that of the previously reported SPE procedure.…”
Section: Resultsmentioning
confidence: 96%
See 1 more Smart Citation
“…It is rapid compared with the previously reported procedures for the separation and determination of lead; [8][9][10][11] the time taken for the separation and analysis of lead in a 500-cm 3 water sample is at most 35 min. The LOD of the method (75 ng per 1000 cm 3 ) is improved by a factor of 67, as it compared with that of the previously reported SPE procedure.…”
Section: Resultsmentioning
confidence: 96%
“…The liquid-liquid extraction and separation of lead ion in the presence of classical [8][9][10] and macrocyclic ligands [11][12][13][14] is frequently reported in the literature. However, classical extraction methods are usually time consuming and labor intensive and require relatively large volumes of high-purity solvents.…”
mentioning
confidence: 99%
“…For the interference assays, lead calibrating solutions with different concentrations of the interferent were prepared from stock solutions of 1 g/l previously attained by weighing and diluting the following substances: Li 2 …”
Section: Reagents and Solutionsmentioning
confidence: 99%
“…Therefore, a preconcentration procedure is required both for minimizing the matrix interferences and improving the detection limit. The preconcentration of heavy metals in natural water has been performed by means of evaporation, solvent extraction 2,3 , ion-exchange and chelating resins [4][5][6][7] as well as coprecipitation. 8 When automating these procedures in continuous-flow units, faster determinations and a better quality of results are attained.…”
mentioning
confidence: 99%