2016
DOI: 10.1016/j.jpcs.2016.04.002
|View full text |Cite
|
Sign up to set email alerts
|

Spectroscopic analysis, AIM, NLO and VCD investigations of acetaldehyde thiosemicarbazone using quantum mechanical simulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
5
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 29 publications
1
5
0
Order By: Relevance
“…According to the Mulliken charge analysis, both the carbons having rich positive due to the electron reduction in N and the related bonds called imine group. This circumstances causing the generation of antibiotic property in the compound which is supported by the literature [13]. The chemical shift of ketonic carbon C5 was 145 ppm which is due to the unequal shield breaking by the highly electronegative atom coupling.…”
Section: Nmr Examinationsupporting
confidence: 71%
See 2 more Smart Citations
“…According to the Mulliken charge analysis, both the carbons having rich positive due to the electron reduction in N and the related bonds called imine group. This circumstances causing the generation of antibiotic property in the compound which is supported by the literature [13]. The chemical shift of ketonic carbon C5 was 145 ppm which is due to the unequal shield breaking by the highly electronegative atom coupling.…”
Section: Nmr Examinationsupporting
confidence: 71%
“…The energy absorbance modulated electronic spectra, NBO and Frontier energy levels have been identified and validated using time-dependent SCF method with suitable basis set. In similar way, the 1 H and 13 C NMR chemical shifts on par with TMS were calculated by GIAO method using I-PCM model with B3LYP/6-311++G(2d,p). The dipole moment, chemical hardness, softness, electrophilicity index and chemical reactivity index were calculated from occupied and unoccupied energy levels.…”
Section: Computational Methodologymentioning
confidence: 99%
See 1 more Smart Citation
“…. The UV-visible spectrum was recorded in the range of 200 to 800 nm, with the scanning interval of 0.2 nm, using the UV-1700 series instrument [10].…”
Section: Physical Statementioning
confidence: 99%
“…The UV-Vis spectrum was recorded in the range of 200 nm to 800 nm, with the scanning interval of 0.2 nm, using the UV-1700 series instrument [12].…”
mentioning
confidence: 99%