1992
DOI: 10.1366/0003702924124213
|View full text |Cite
|
Sign up to set email alerts
|

Spectroscopic Investigation of Fluorescence Quenching Agents: Effect of Nitromethane on the Fluorescence Emission Behavior of Select Cyclopenta-PAH, Aceanthrylene, and Fluorene Derivatives

Abstract: Nitromethane is examined as a selective fluorescence quenching agent for “alternant” alkyl-substituted polycyclic aromatic hydrocarbons (PAHs). Fluorescence emission behavior is reported for 11 H-benz[bc]aceanthrylene, 4 H-cyclopenta[def]phenanthrene, 4 H-cyclopenta[def]chrysene, 13 H-dibenzo[a,g]fluorene, 13 H-dibenzo[a,i]fluorene, 4 H-benzo[b]cyclopenta[mno]chrysene, 4 H-cyclopenta[pqr]picene, 7 H-dibenzo[c,g]fluorene, 9 H-benz(6,7)indeno[1,21]phenanthrene, 4 H-benzo[b]cyclopenta[jkl]triphenylene, 13 H-diben… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

1992
1992
2003
2003

Publication Types

Select...
10

Relationship

6
4

Authors

Journals

citations
Cited by 37 publications
(8 citation statements)
references
References 30 publications
0
8
0
Order By: Relevance
“…Mathematical expressions, computational procedures, and interrogation zone dimensions are given elsewhere. [17][18][19]26,27 Every effort was made to work at solution absorbances below Acm -~ _< 0.95 ([prim -< 3.00) where the inner-filtering correction equation is valid. Secondary inner-filtering corrections were not necessary in the present study since nitromethane is "optically transparent" in most of these PAHs' emission ranges.…”
Section: Methodsmentioning
confidence: 99%
“…Mathematical expressions, computational procedures, and interrogation zone dimensions are given elsewhere. [17][18][19]26,27 Every effort was made to work at solution absorbances below Acm -~ _< 0.95 ([prim -< 3.00) where the inner-filtering correction equation is valid. Secondary inner-filtering corrections were not necessary in the present study since nitromethane is "optically transparent" in most of these PAHs' emission ranges.…”
Section: Methodsmentioning
confidence: 99%
“…Interestingly, not all PANHs behave in this fashion. Various emission intensity ratios of 1-azapyrene, 2-azapyrene, 4-azapyrene, 4-azachrysene, benzo[lmn]- [3,8]phenanthroline, and benzo [4,10]anthra [1,9,Scdef]-cinnoline remained constant, irrespective of solvent polarity. Fluorescence emission spectra of benzo[a]-phenazine, acenaphtho [1,2]pyridine, indeno [1,2,3ij]-isoquinoline, and indeno [1,2,3ij] [2,7]naphthyridine showed very little structured emission.…”
Section: Protonatedmentioning
confidence: 99%
“…Several workers have used the second-derivative technique to increase the selectivity of synchronous spectroscopy for determining different compounds in samples of motor oil, waters and human serum. [22][23][24] Several papers in which the quenching of PAHs by other compounds such as chlorine 25 was described and studies in which nitromethane was evaluated as a selective quenching agent for alternant alkyl-substituted PAHs 26,27 have been published recently. However, the different studies published on the simultaneous determination of several PAHs by synchronous luminescence did not describe the possibility of quenching of fluorescence of some compounds (PAHs) by others present in the mixture.…”
Section: Introductionmentioning
confidence: 99%