2015
DOI: 10.1016/j.jnoncrysol.2015.08.015
|View full text |Cite
|
Sign up to set email alerts
|

Specular reflectance (SR) and attenuated total reflectance (ATR) infrared (IR) spectroscopy of transparent flat glass surfaces: A case study for soda lime float glass

Abstract: This paper describes the optical principles of specular reflection (SR) and attenuated total reflection (ATR)-infrared (IR) spectroscopy, both of which are useful methods for glass surface analyses. It should be noted that the shape, position, and relative intensity of peaks in reflectance spectra vary drastically depending on the IR incidence angle as well as the probe method (SR vs. ATR). For example, in SR-IR analyses of soda lime glass, the Si-O-Si stretch band shows a blue-shift from its original position… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
79
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 70 publications
(81 citation statements)
references
References 30 publications
2
79
0
Order By: Relevance
“…In principle, the Kramers‐Kronig (KK) algorithm can be used to convert the experimental reflectance spectrum to the spectrum; but many commercial KK conversions does not work reliably for the silicate bands of glass. In such cases, the reflectance spectra could be used as an alternative (but, caution must be taken since the true peak position might be different) . In most experimental works reported in the literature (and Figure as well), the maximum intensity position (ω mp ) is normally used, which corresponds to the most probable value in the distribution.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In principle, the Kramers‐Kronig (KK) algorithm can be used to convert the experimental reflectance spectrum to the spectrum; but many commercial KK conversions does not work reliably for the silicate bands of glass. In such cases, the reflectance spectra could be used as an alternative (but, caution must be taken since the true peak position might be different) . In most experimental works reported in the literature (and Figure as well), the maximum intensity position (ω mp ) is normally used, which corresponds to the most probable value in the distribution.…”
Section: Resultsmentioning
confidence: 99%
“…Also, artificial jumps of ions across the periodic boundary in the MD trajectory were removed in this calculation. The real and imaginary components of complex refractive index (nnormalω=nnormalω+iknormalω) were calculated from the complex dielectric constant ϵitalicω and the reflectance spectrum (Rnormalω=nnormalω.n)(ω) was calculated from the complex refractive index …”
Section: Experimental and Simulation Methodsmentioning
confidence: 99%
“…A gold mirror was used as a reference background. The approximate information depth from SR‐IR analysis is 0.5‐2 μm in the Si–OH and Si–O–Si asymmetric stretching vibration region (900‐1100 cm −1 ) . Attenuated total reflectance IR (ATR‐IR) spectroscopy was performed with a Bruker Hyperion 3000 Microscope (Bruker, Co.) equipped with a Ge ATR crystal with 60 incidence angle and a Bruker V70 (Bruker, Co) equipped with a diamond ATR crystal with 45 incidence angle.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…~420 N was applied from diamond crystal over 1.5 mm 2 area during the ATR‐IR analysis. Based on the refractive index of the pristine SLS glass, the information depth of ATR‐IR in the spectral range between 4000 cm −1 and 1200 cm −1 is estimated to be 0.5‐1.75 μm when the Ge crystal is used and 1.5‐2.5 μm when the diamond crystal is used …”
Section: Experimental Methodsmentioning
confidence: 99%
“…() and (), respectively. The small difference in the peak position between the absorbance and reflectance data is due to the dispersion effect in reflection [Color figure can be viewed at wileyonlinelibrary.com]…”
Section: Introductionmentioning