Spektrometer für experimentelle Untersuchungen der Wasserdampfdiffusion in Gasen (Spectrometer for Experimental Investigation of Water Vapour Diffusion in Gases)

Abstract: Diffusionsprozesse spielen in vielen verfahrenstechnischenBereichen eine wichtige Rolle, allerdings stehen geeignete Messverfahren zur lokalen Konzentrationsbestimmung nur in beschränktem Umfang zur Verfügung. Ein Diodenlaser-Absorptionsspektrometer wurde entwickelt, welches entlang dem kurzen, kollimierten Messstrahl integrierte WasserdampfKonzentrationsmessungen mit einer lateralen Auflösung von 200 µm ermöglicht. Es wurden Konzentrationsprofile in teilweise mit Wasser gefüllten Standardküvetten vermessen un… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2003
2003
2003
2003

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 3 publications
0
3
0
Order By: Relevance
“…The absorption signal at the lock-in amplifier resembled the second derivative of the pressure-broadened absorption line profile. The amplitude of the absorption feature S was evaluated by signal processing routines described in [1,2]. The signal was also normalized to the broadband overall transmission, was obtained separately from the detector DC signal [3].…”
Section: Laser Spectrometermentioning
confidence: 99%
See 2 more Smart Citations
“…The absorption signal at the lock-in amplifier resembled the second derivative of the pressure-broadened absorption line profile. The amplitude of the absorption feature S was evaluated by signal processing routines described in [1,2]. The signal was also normalized to the broadband overall transmission, was obtained separately from the detector DC signal [3].…”
Section: Laser Spectrometermentioning
confidence: 99%
“…The overall interference background could be reduced to below the absorption signal caused by the water vapour background for a residual relative humidity of 5%. Further details about the optical layout can be found in [2]. All optical components were mounted on a small optical bench, which was vertically traversable (y-direction) by a precision stepping motor (Micos MT-65) with a resolution of 0.1 µm and a range of 25 mm.…”
Section: Optical Setupmentioning
confidence: 99%
See 1 more Smart Citation