1982
DOI: 10.2172/59740
|View full text |Cite
|
Sign up to set email alerts
|

Spent-fuel dry-storage testing at E-MAD (March 1978-March 1982)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0
5

Year Published

1986
1986
2023
2023

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 0 publications
0
3
0
5
Order By: Relevance
“…At the times indicated in Table E.1 in Appendix E, 500-mL gas samples were removed from the canisters containing the individual spent fuel assemblies. The procedure used to obtain the samples depended on the canister and type of test in progress and are described in detail by Unterzuber et al (1982). The procedures used for the unwelded (air atmosphere) canisters, the encapsulated canisters (He), and the FAITM canisters (air/He/vacuum) are briefly described.…”
Section: Monitoring Of Gas Samplesmentioning
confidence: 99%
See 1 more Smart Citation
“…At the times indicated in Table E.1 in Appendix E, 500-mL gas samples were removed from the canisters containing the individual spent fuel assemblies. The procedure used to obtain the samples depended on the canister and type of test in progress and are described in detail by Unterzuber et al (1982). The procedures used for the unwelded (air atmosphere) canisters, the encapsulated canisters (He), and the FAITM canisters (air/He/vacuum) are briefly described.…”
Section: Monitoring Of Gas Samplesmentioning
confidence: 99%
“…Oecay heat rates were measured for fuel assembl i es B43, D03, 015, 022 and 034 using a hailing water calori~eter hoth hefore testing and after storage. The results of these measurements are listed in Tahle B.1 and compared with the predicted riecay heat generation in Figures B.1, B.2, B.3, and The relationship between the canister temperatures measured in dry storage demonstration tests and the peak fuel cladding temperature was developed from data obtained from the FAITM test during the period between 1979 and 1981 by the procedure documented by Unterzuber (1982).…”
Section: Appendix B Decay Heat Measurementsmentioning
confidence: 99%
“…This section contains a brief description of the test hardware and test conditions needed for numerical simulation. A full account of all test details is available In Unterzuber et al (1982). A condensed but complete summary of details needed for simulation is contained in Sates (1986).…”
Section: Test Descriptionmentioning
confidence: 99%
“…A medida que en muchos reactores de los Estados Unidos las piscinas de combustible nuclear irradiado empezaron a llenarse, comenzó a crecer la necesidad de un almacenamiento alternativo. Por ello, en los años 80 se llevaron a cabo numerosas campañas experimentales (Unterzuber, R. et al, 1982;Bates, 1986;Dziadosz, D. et al, 1986;. Algunos de estos trabajos se realizaron a pequeña escala (Unterzuber, R. et al, 1982;Bates, 1986;, es decir, un solo elemento de combustible (real o maqueta) donde las condiciones de contorno simuladas son similares a las del almacenamiento en seco.…”
Section: 51experimentalesunclassified
“…Por ello, en los años 80 se llevaron a cabo numerosas campañas experimentales (Unterzuber, R. et al, 1982;Bates, 1986;Dziadosz, D. et al, 1986;. Algunos de estos trabajos se realizaron a pequeña escala (Unterzuber, R. et al, 1982;Bates, 1986;, es decir, un solo elemento de combustible (real o maqueta) donde las condiciones de contorno simuladas son similares a las del almacenamiento en seco. Además, multitud de trabajos se realizaron a media o gran escala (Dziadosz, D. et al, 1986;McKinnon, M.A.…”
Section: 51experimentalesunclassified