“…Since it is not possible to rotate the "weak" magnetic 054430-3 Bragg peak at (0, ±1, 1.5) positions onto the detector bank at fixed E i , one cannot use the above-mentioned method to directly measure the sample assembly detwinning ratio, defined as η = [I (1, 0, 1.5) − I (0, 1, 1.5)]/[I (1, 0, 1.5) + I (0, 1, 1.5)], where I (1, 0, 1.5) and I (0, 1, 1.5) correspond to the strong and weak magnetic Bragg peaks, respectively [22]. Nevertheless, one can still determine the sample detwinning ratio η using the low-energy inelastic part of the spin fluctuation spectrum, which at least provides a firm lower bound, and was in fact observed to have one-to-one correspondence to η in previous experiments on the NaFeAs and BaFe 2 As 2 systems [22,23].…”