Spinal cord stimulation: a review of the safety literature and proposal for perioperative evaluation and management

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
27
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(27 citation statements)
references
References 46 publications
0
27
0
Order By: Relevance
“…MRI compatible stimulation technology is evolving, and functional MRI (fMRI) for investigational research might be feasible as part of the study design, pending appropriate regulatory approvals. The current commercially available spinal stimulators are still contraindicated for MRI, as the artifacts may be problematic and risks of tissue heating in this application are still unknown [27]. Thus, careful imaging of the spinal cord should be completed before implantation of a stimulator.…”
Section: Section III Clinical Testing and Trainingmentioning
confidence: 99%
“…MRI compatible stimulation technology is evolving, and functional MRI (fMRI) for investigational research might be feasible as part of the study design, pending appropriate regulatory approvals. The current commercially available spinal stimulators are still contraindicated for MRI, as the artifacts may be problematic and risks of tissue heating in this application are still unknown [27]. Thus, careful imaging of the spinal cord should be completed before implantation of a stimulator.…”
Section: Section III Clinical Testing and Trainingmentioning
confidence: 99%
“…A patient, implanted with deep brain stimulator, reported a shocking sensation, described as "lancinating" when exposed to monopolar cautery during a dermatologic procedure (26). Therefore, all 5 SCS companies recommend avoidance of monopolar electrocautery in a patient with SCS (18-22) Bipolar electrocautery is recommended if electrocautery is required (2). Different from the monopolar mode, bipolar does not require a grounding pad; the active and return electrodes are on opposite ends of the forceps, limiting energy dispersion (27).…”
Section: Electrocauterymentioning
confidence: 99%
“…Current operating room recommendations, including turning the device to the lowest setting and then powering off, should be followed. Finally, the SCS must be interrogated after the procedure to ensure proper setting and working order (2,19,21).…”
Section: Electrocauterymentioning
confidence: 99%