2013
DOI: 10.1371/journal.pone.0072950
|View full text |Cite
|
Sign up to set email alerts
|

Spiral-Wave Dynamics in a Mathematical Model of Human Ventricular Tissue with Myocytes and Fibroblasts

Abstract: Cardiac fibroblasts, when coupled functionally with myocytes, can modulate the electrophysiological properties of cardiac tissue. We present systematic numerical studies of such modulation of electrophysiological properties in mathematical models for (a) single myocyte-fibroblast (MF) units and (b) two-dimensional (2D) arrays of such units; our models build on earlier ones and allow for zero-, one-, and two-sided MF couplings. Our studies of MF units elucidate the dependence of the action-potential (AP) morpho… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
72
0
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
3
2
1

Relationship

1
5

Authors

Journals

citations
Cited by 63 publications
(76 citation statements)
references
References 83 publications
(171 reference statements)
3
72
0
1
Order By: Relevance
“…We check the accuracy of our numerical scheme, as in Ref. [28], by varying both δt and δx in a cable-type domain of myocytes [7,26] and by measuring CV of a plane wave, which is injected into the domain by stimulating its left boundary for 3 ms with a stimulus of strength 150 pA. With δx = 0.25 mm, CV increases by 1.1% when we change δt from 0.02 to 0.01 ms; if we decrease δx from 0.25 to 0.15 mm, with δt = 0.02 ms, then CV increases by 3.1%; these changes are similar to those found in other studies [22,26,28,29].…”
Section: B Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…We check the accuracy of our numerical scheme, as in Ref. [28], by varying both δt and δx in a cable-type domain of myocytes [7,26] and by measuring CV of a plane wave, which is injected into the domain by stimulating its left boundary for 3 ms with a stimulus of strength 150 pA. With δx = 0.25 mm, CV increases by 1.1% when we change δt from 0.02 to 0.01 ms; if we decrease δx from 0.25 to 0.15 mm, with δt = 0.02 ms, then CV increases by 3.1%; these changes are similar to those found in other studies [22,26,28,29].…”
Section: B Methodsmentioning
confidence: 99%
“…The full sets of equations for this model, including the ODEs for the ion-channel gating variables and the ion dynamics, are given in Refs. [7,26].…”
Section: A Modelmentioning
confidence: 99%
See 3 more Smart Citations