2013
DOI: 10.1016/j.talanta.2012.10.033
|View full text |Cite
|
Sign up to set email alerts
|

Square-wave voltammetric determination of bezafibrate in pharmaceutical formulations using a cathodically pretreated boron-doped diamond electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
27
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 35 publications
(28 citation statements)
references
References 28 publications
1
27
0
Order By: Relevance
“…A linear relationship was observed between log I p against log v with a slope of 0.5282 (R 2 = 0.9982, n = 6), as shown in Figure 3. The slope of 0.5282 was close to the theoretical value of 0.5, which indicated that the reduction process of RB5 dye was mainly controlled by diffusion [30,31]. The effect of the RB5 dye concentrations was investigated and the results showed that the E p of RB5 dye at -258 mV showed no significant change in the peak position and the I p of the RB5 dye increased with the increasing concentration of RB5 dye.…”
Section: Results and Discussion Electrochemical Behaviour Of The Rb5 Dyesupporting
confidence: 71%
“…A linear relationship was observed between log I p against log v with a slope of 0.5282 (R 2 = 0.9982, n = 6), as shown in Figure 3. The slope of 0.5282 was close to the theoretical value of 0.5, which indicated that the reduction process of RB5 dye was mainly controlled by diffusion [30,31]. The effect of the RB5 dye concentrations was investigated and the results showed that the E p of RB5 dye at -258 mV showed no significant change in the peak position and the I p of the RB5 dye increased with the increasing concentration of RB5 dye.…”
Section: Results and Discussion Electrochemical Behaviour Of The Rb5 Dyesupporting
confidence: 71%
“…whether they are predominantly hydrogen or oxygen terminated [21]; the predominance of a termination type can be attained by proper electrochemical pretreatments. This effect of surface termination was observed, for instance, in the determination of additives in food products [22][23][24] and of drugs in pharmaceutical formulations [25][26][27][28], when cathodically pretreated (predominantly hydrogen-terminated) BDD electrodes presented better performances.…”
Section: Introductionmentioning
confidence: 82%
“…Consequently, all subsequent experiments were carried out using a cathodically pretreated BDD. Previously, better results were also obtained in the analysis of several analytes when a predominantly hydrogen-terminated BDD electrode was used [22,24,25,28,35].…”
Section: Abz Determinationmentioning
confidence: 99%
“…As has been previously summarized [32], increased electroanalytical performances have been attained in the determination of additives in food products and drugs in pharmaceutical formulations after the BDD electrode was cathodically pretreated; more recently, this has happened e.g. for food colorants [33], and the pharmaceuticals albendazole [34], propylthiouracil [35], bezafibrate [36], hydroxychloroquine [37], hydroquinone [38], diclofenac [39], ciprofloxacin [40], and paracetamol/caffeine/orphenadrine [41] or propanolol/hydrochlorothiazide [42] simultaneously. However, in some cases, better results were attained with an anodically pretreated BDD electrode, e.g.…”
Section: Introductionmentioning
confidence: 99%