2014
DOI: 10.1016/j.ijepes.2014.05.033
|View full text |Cite
|
Sign up to set email alerts
|

Stability analysis and reactive power compensation issue in a microgrid with a DFIG based WECS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
14
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 45 publications
(15 citation statements)
references
References 19 publications
0
14
0
1
Order By: Relevance
“…Hybrid microgrid generally refers to combination of AC and DC microgrids or different combinations of Distributed Energy Resources (DER) or combination of DER with different control strategy etc., In all these cases the important thing to be maintained in the microgrid is the system stability. In the proceeding context different hybrid microgrid structures with different controls are discussed in [29], [30], [31] and [32]. The small signal stability of the multi machine power system (say IEEE-9 bus system is considered in this paper) is analysed, with and without the connection of a MG by D. Padma Subramanian et all in [31].…”
Section: Stability Analysis In Hybrid Micro Systemsmentioning
confidence: 99%
See 1 more Smart Citation
“…Hybrid microgrid generally refers to combination of AC and DC microgrids or different combinations of Distributed Energy Resources (DER) or combination of DER with different control strategy etc., In all these cases the important thing to be maintained in the microgrid is the system stability. In the proceeding context different hybrid microgrid structures with different controls are discussed in [29], [30], [31] and [32]. The small signal stability of the multi machine power system (say IEEE-9 bus system is considered in this paper) is analysed, with and without the connection of a MG by D. Padma Subramanian et all in [31].…”
Section: Stability Analysis In Hybrid Micro Systemsmentioning
confidence: 99%
“…Paper [29] discusses the transient behaviour of the MG in islanded mode which comprises of DFIG based wind turbine and a diesel generator. The heuristic nature of this hybrid system is that, MG results in insufficient supply of reactive power to the loads.…”
Section: Stability Analysis In Hybrid Micro Systemsmentioning
confidence: 99%
“…For standalone operation, diesel power plays a great role, acting as backup power in several hybrid power generation systems. Despite showing simplicity in its functioning and providing reactive power for better voltage regulation [5][6][7][8], diesel power is less reliable. There are lots of operational constraints with regard to environmental and economical issues.…”
Section: Introductionmentioning
confidence: 99%
“…STATCOM as a comprehensive compensator was suggested for microgrids . It was shown that the UPFC and STATCOM are better choices for reactive power and voltage in typical IHPS . Application of the model predictive control approach for voltage stability in an isolated hybrid wind‐diesel generation system based on reactive power control was studied in Kassem and Abdelaziz .…”
Section: Introductionmentioning
confidence: 99%