Stability of plasma electrolytes in Barricor and PST II tubes under different storage conditions

Abstract: IntroductionSample stability can be influenced by many different factors; evaporation and leakage from residual cells are the most relevant factors for electrolytes. During the analytical phase, samples are usually kept uncapped at room temperature. Once samples are processed, they are usually stored sealed and refrigerated. Long turnaround time and the possibility of “add-on test” need consideration for electrolyte stability. The aim of our study is to examine short-term electrolyte stability in this two-comm… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…However, higher concentrations of K in the tubes with a barrier than in the barrier-free LiH tubes may be due to prolonged cell contact, but further investigation is needed to explain the underlying cause. In a recent study on sample stability, the basal K concentrations in Barricor plasma were lower than the K concentrations in Plasma Separator (PST) plasma in contrast to these findings ( 20 ). Therefore, it is necessary to evaluate these Barricor tubes in different settings to clarify the net effects.…”
Section: Discussionmentioning
confidence: 88%
“…However, higher concentrations of K in the tubes with a barrier than in the barrier-free LiH tubes may be due to prolonged cell contact, but further investigation is needed to explain the underlying cause. In a recent study on sample stability, the basal K concentrations in Barricor plasma were lower than the K concentrations in Plasma Separator (PST) plasma in contrast to these findings ( 20 ). Therefore, it is necessary to evaluate these Barricor tubes in different settings to clarify the net effects.…”
Section: Discussionmentioning
confidence: 88%
“…According to the manufacturer, the quality of plasma is improved, the centrifugation time is shorter (3 min vs. 10 min with BD Vacutainer® lithium heparin tubes) and post centrifugation analyte concentrations are more stable in samples that have been stored in the primary tube. At this time, some studies have been published to verify if these tubes are an effective alternative to gel barrier tubes ( 3 - 5 ). Nevertheless, these publications concern mainly the correlations between results obtained using different tubes for biochemical parameters, particularly cardiac markers, without stability studies ( 3 , 4 ).…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, these publications concern mainly the correlations between results obtained using different tubes for biochemical parameters, particularly cardiac markers, without stability studies ( 3 , 4 ). The one study which has investigated different storage conditions relates only to electrolytes ( 5 ). Given this lack of data, we aimed to compare results for nine biochemical tests from the BD Vacutainer® lithium heparin tubes vs. the BD Barricor™ plasma tubes and to determine plasma stability of analytes after centrifugation according to our routine laboratory practice.…”
Section: Introductionmentioning
confidence: 99%
“…As described in literature, serum displays a better sample stability compared to plasma ( 4 ). This is mostly attributed to blood cells remaining in plasma in higher concentration than in serum.…”
Section: Discussionmentioning
confidence: 86%
“…In recent years, only few BD Barricor tube evaluations were performed, mostly encompassing samples from healthy participants ( 4 , 7 , 13 - 15 ). Nevertheless, to the best of our knowledge, this is the first study evaluating BD Barricor tubes in relation to BD RST tubes in terms of analytes’ comparability and long-term stability of 25 analytes from in-patient samples.…”
Section: Discussionmentioning
confidence: 99%